Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2017 Oct 5;50(4):1700451.
doi: 10.1183/13993003.00451-2017. Print 2017 Oct.

Long-term effects of inhaled corticosteroids on sputum bacterial and viral loads in COPD

Affiliations
Randomized Controlled Trial

Long-term effects of inhaled corticosteroids on sputum bacterial and viral loads in COPD

Marco Contoli et al. Eur Respir J. .

Abstract

Inhaled corticosteroid-containing medications reduce the frequency of COPD exacerbations (mainly infectious in origin) while paradoxically increasing the risk of other respiratory infections. The aim was to determine the effects of inhaled corticosteroids on airway microbial load in COPD patients and evaluate the influence of the underlying inflammatory profile on airway colonisation and microbiome.This is a proof-of-concept prospective, randomised, open-label, blinded endpoint study. Sixty patients with stable moderate COPD were randomised to receive one inhalation twice daily of either a combination of salmeterol 50 μg plus fluticasone propionate 500 μg or salmeterol 50 μg for 12 months. The primary outcome was the change of sputum bacterial loads over the course of treatment.Compared with salmeterol, 1-year treatment with salmeterol plus fluticasone was associated with a significant increase in sputum bacterial load (p=0.005), modification of sputum microbial composition and increased airway load of potentially pathogenic bacteria. The increased bacterial load was observed only in inhaled corticosteroid-treated patients with lower baseline sputum or blood eosinophil (≤2%) levels but not in patients with higher baseline eosinophils.Long-term inhaled corticosteroid treatment affects bacterial load in stable COPD. Lower eosinophil counts are associated with increased airway bacterial load.

Trial registration: ClinicalTrials.gov NCT01213693.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest: Disclosures can be found alongside this article at erj.ersjournals.com

Comment in

Publication types

MeSH terms

Associated data

LinkOut - more resources