Impact of preprocedure simethicone on adenoma detection rate during colonoscopy: a multicenter, endoscopist-blinded randomized controlled trial
- PMID: 28985630
- DOI: 10.1055/s-0043-119213
Impact of preprocedure simethicone on adenoma detection rate during colonoscopy: a multicenter, endoscopist-blinded randomized controlled trial
Abstract
Background and study aims: Ideal bowel preparation for colonoscopy requires complete removal of fluid and foam from the colon. Polyethylene glycol (PEG) is widely used for bowel preparation, with antifoaming agents such as simethicone commonly used in combination with PEG. Data on the effect of simethicone on the adenoma detection rate (ADR) were limited. This study therefore aimed to investigate whether preprocedure simethicone could increase the ADR.
Patients and methods: This was a prospective, multicenter, endoscopist-blinded randomized controlled trial involving consecutive patients who underwent colonoscopy in six centers in China. Patients were randomly assigned to one of two groups: PEG plus simethicone or PEG alone. The primary outcome was ADR; secondary outcomes were quality of bowel preparation, measured by the Boston bowel preparation scale (BBPS) and bubble scores.
Results: 583 patients were included. More adenomas were detected in the PEG plus simethicone group than in the PEG alone group (ADR 21.0 % vs. 14.3 %, P = 0.04; advanced ADR 9.0 % vs. 7.0 %, P = 0.38). The mean number of adenomas detected was 2.20 ± 1.36 vs. 1.63 ± 0.89 (P = 0.02). Patients in the PEG plus simethicone group showed better bowel cleansing efficacy: BBPS ≥ 6 in 88.3 % vs. 75.2 % (P < 0.001) and bubble scores of 1.00 ± 1.26 vs. 3.98 ± 2.50 (P < 0.001). Abdominal bloating was reported less frequently in the PEG plus simethicone group (7.8 % vs. 19.7 %, P < 0.001) than in the PEG alone group.
Conclusion: Combined use of PEG and simethicone is associated with a significantly increased ADR in a Chinese population.
Trial registration: ClinicalTrials.gov NCT02540239.
© Georg Thieme Verlag KG Stuttgart · New York.
Conflict of interest statement
None
Comment in
-
Video Comment on Yu Bai et al.Endoscopy. 2018 Feb;50(2):v7. doi: 10.1055/s-0043-123975. Epub 2018 Jan 29. Endoscopy. 2018. PMID: 29378367 No abstract available.
-
[French comment on article Impact of preprocedure simethicone on adenoma detection rate during colonoscopy: a multicenter, endoscopist-blinded randomized controlled trial].Endoscopy. 2018 Feb;50(2):190. doi: 10.1055/s-0043-125217. Epub 2018 Jan 29. Endoscopy. 2018. PMID: 29378376 French. No abstract available.
Publication types
MeSH terms
Substances
Associated data