Chest compression during sustained inflation versus 3:1 chest compression:ventilation ratio during neonatal cardiopulmonary resuscitation: a randomised feasibility trial
- PMID: 28988159
- DOI: 10.1136/archdischild-2017-313037
Chest compression during sustained inflation versus 3:1 chest compression:ventilation ratio during neonatal cardiopulmonary resuscitation: a randomised feasibility trial
Abstract
Background: Current neonatal resuscitation guidelines recommend 3:1 compression:ventilation (C:V) ratio. Recently, animal studies reported that continuous chest compressions (CC) during a sustained inflation (SI) significantly improved return of spontaneous circulation (ROSC). The approach of CC during SI (CC+SI) has not been examined in the delivery room during neonatal resuscitation.
Hypothesis: It is a feasibility study to compare CC+SI versus 3:1 C:V ratio during neonatal resuscitation in the delivery room. We hypothesised that during neonatal resuscitation, CC+SI will reduce the time to ROSC. Our aim was to examine if CC+SI reduces ROSC compared with 3:1 C:V CPR in preterm infants <33 weeks of gestation.
Study design: Randomised feasibility trial.
Method: Once CC was indicated all eligible infants were immediately and randomly allocated to either CC+SI group or 3:1 C:V group. A sequentially numbered, brown, sealed envelope contained a folded card box with the treatment allocation was opened by the clinical team at the start of CC.
Study interventions: Infants in the CC+SI group received CC at a rate of 90/min during an SI with a duration of 20 s (CC+SI). After 20 s, the SI was interrupted for 1 s and the next SI was started for another 20 s until ROSC. Infants in the '3:1 group' received CC using 3:1 C:V ratio until ROSC.
Primary outcome: Overall the mean (SD) time to ROSC was significantly shorter in the CC+SI group with 31 (9) s compared with 138 (72) s in the 3:1 C:V group (p=0.011).
Conclusion: CC+SI is feasible in the delivery room.
Trial registration number: Clinicaltrials.gov NCT02083705, pre-results.
Keywords: chest compression; delivery room; neonatology; newborn; sustained inflation.
© Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Conflict of interest statement
Competing interests: None declared.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical