Abstract
A quality-made dental impression is a prerequisite for successful fixed-prosthodontic fabrication and is directly dependent on the dimensional stability, accuracy and flexibility of the elastomeric impression materials, as well as on the appropriately used impression techniques. The purpose of this paper is to provide a literature review of relevant scientific papers which discuss the use of various silicone impression materials, different impression techniques and to evaluate their impact on the dimensional stability and accuracy of the obtained impressions. Scientific papers and studies were selected according to the materials used, the sample size, impression technique, storage time, type of measurements and use of spacer for the period between 2002 and 2016. In the reviewed literature several factors that influence the dimensional stability and accuracy of silicone impression molds, including the choice of the type of viscosity, impression material thickness, impression technique, retention of the impression material on the tray, storage time before the casting, number of castings, hydrophilicity of the material, release of byproducts, contraction after polymerization, thermal contraction and incomplete elastic recovery were presented. The literature review confirmed the lack of standardization of methodologies applied in the research and their great diversity. All findings point to the superiority of the addition silicone compared to the condensation silicone.
Keywords: dimensional stability; fixed partial dentures; impression technique; review; silicone impression material.
Similar articles
-
Experimental study on the use of spacer foils in two-step putty and wash impression procedures using silicone impression materials.J Prosthet Dent. 2015 Apr;113(4):316-22. doi: 10.1016/j.prosdent.2014.09.014. Epub 2014 Nov 25. J Prosthet Dent. 2015. PMID: 25453563
-
Dimensional accuracy of dental casts: influence of tray material, impression material, and time.J Prosthodont. 2002 Jun;11(2):98-108. J Prosthodont. 2002. PMID: 12087547
-
An in vitro study on the dimensional stability of a vinyl polyether silicone impression material over a prolonged storage period.J Prosthet Dent. 2013 Mar;109(3):172-8. doi: 10.1016/S0022-3913(13)60038-4. J Prosthet Dent. 2013. PMID: 23522366
-
Dimensional stability of elastomeric impression materials: a critical review of the literature.Eur J Prosthodont Restor Dent. 2011 Dec;19(4):163-6. Eur J Prosthodont Restor Dent. 2011. PMID: 22645802 Review.
-
Impression materials in fixed prosthodontics: influence of choice on clinical procedure.J Prosthodont. 2011 Feb;20(2):153-60. doi: 10.1111/j.1532-849X.2010.00673.x. Epub 2011 Feb 1. J Prosthodont. 2011. PMID: 21284760 Review.
Cited by
-
Trueness evaluation of three intraoral scanners for the recording of maximal intercuspal position.Hua Xi Kou Qiang Yi Xue Za Zhi. 2024 Apr 1;42(2):227-233. doi: 10.7518/hxkq.2024.2023277. Hua Xi Kou Qiang Yi Xue Za Zhi. 2024. PMID: 38597082 Free PMC article. Chinese, English.
-
Synthesis of a novel injectable alginate impression material and impression accuracy evaluation.Hua Xi Kou Qiang Yi Xue Za Zhi. 2022 Dec 1;40(6):662-667. doi: 10.7518/hxkq.2022.06.006. Hua Xi Kou Qiang Yi Xue Za Zhi. 2022. PMID: 36416318 Free PMC article. Chinese, English.
-
Digital impressions in dentistry-accuracy of impression digitalisation by desktop scanners.Clin Oral Investig. 2020 Mar;24(3):1249-1257. doi: 10.1007/s00784-019-02995-w. Epub 2019 Jul 13. Clin Oral Investig. 2020. PMID: 31302771
-
Effect of Ultraviolet C light disinfection on the dimensional stability of dental impression materials: A scoping review of the literature.J Clin Exp Dent. 2024 Nov 1;16(11):e1422-e1428. doi: 10.4317/jced.62119. eCollection 2024 Nov. J Clin Exp Dent. 2024. PMID: 39670026 Free PMC article.
-
Accuracy of Dental Models Fabricated Using Recycled Poly-Lactic Acid.Materials (Basel). 2023 Mar 25;16(7):2620. doi: 10.3390/ma16072620. Materials (Basel). 2023. PMID: 37048914 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources