Performance of the Xpert MTB/RIF assay for the diagnosis of pulmonary tuberculosis and rifampin resistance in a low-incidence, high-resource setting
- PMID: 29016684
- PMCID: PMC5633176
- DOI: 10.1371/journal.pone.0186139
Performance of the Xpert MTB/RIF assay for the diagnosis of pulmonary tuberculosis and rifampin resistance in a low-incidence, high-resource setting
Abstract
Performance of the Xpert MTB/RIF assay, designed to simultaneously detect Mycobacterium tuberculosis complex (MTBC) and rifampin (RIF) resistance, has been well documented in low-resource settings with high TB-incidence. However, few studies have assessed its accuracy in low TB incidence settings. We evaluated the performance of Xpert MTB/RIF using clinical sputum specimens routinely collected from suspect pulmonary TB patients over a 4-year time period in San Diego County, California. Xpert MTB/RIF results were compared to acid-fast bacilli (AFB) smear microscopy, mycobacterial culture, and phenotypic drug susceptibility testing (DST). Of 751 sputum specimens, 134 (17.8%) were MTBC culture-positive and 2 (1.5%) were multidrug-resistant (MDR). For the detection of MTBC, Xpert MTB/RIF sensitivity was 89.6% (97.7% and 74.5% in smear-positive and -negative sputa, respectively) and specificity was 97.2%; while AFB smear sensitivity and specificity were 64.9% and 77.8%, respectively. Xpert MTB/RIF detected 35 of 47 smear-negative culture-positive specimens, and excluded 124 of 137 smear-positive culture-negative specimens. Xpert MTB/RIF also correctly excluded 99.2% (121/122) of nontuberculous mycobacteria (NTM) specimens, including all 33 NTM false-positives by smear microscopy. For the detection of RIF resistance, Xpert MTB/RIF sensitivity and specificity were 100% and 98.3%, respectively. Our findings demonstrate that Xpert MTB/RIF is able to accurately detect MTBC and RIF resistance in routinely collected respiratory specimens in a low TB-incidence setting, with comparable performance to that achieved in high-incidence settings; and suggest that under these conditions the assay has particular utility in detecting smear-negative TB cases, excluding smear-positive patients without MTBC disease, and differentiating MTBC from NTM.
Conflict of interest statement
References
-
- World Health Organization (WHO). Global Tuberculosis Report 2016. WHO/HTM/TB/2016.13. Geneva; 2016.
-
- World Health Organization (WHO)—Stop TB Partnership. The Global Plan to End TB 2016–2020: The Paradigm Shift. Geneva; 2015.
-
- Centers for Disease Control and Prevention (CDC). Controlling tuberculosis in the United States: recommendations from the American Thoracic Society, CDC, and the Infectious Diseases Society of America. MMWR Morb Mortal Wkly Rep. 2005;54: 1–81. - PubMed
-
- Steingart KR, Ng V, Henry M, Hopewell PC, Ramsay A, Cunningham J, et al. Sputum processing methods to improve the sensitivity of smear microscopy for tuberculosis: a systematic review. Lancet Infect Dis. 2006;6: 664–74. doi: 10.1016/S1473-3099(06)70602-8 - DOI - PubMed
-
- Steingart KR, Henry M, Ng V, Hopewell PC, Ramsay A, Cunningham J, et al. Fluorescence versus conventional sputum smear microscopy for tuberculosis: a systematic review. Lancet Infect Dis. 2006;6: 570–81. doi: 10.1016/S1473-3099(06)70578-3 - DOI - PubMed
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources