Diagnostic Accuracy of the Aortic Dissection Detection Risk Score Plus D-Dimer for Acute Aortic Syndromes: The ADvISED Prospective Multicenter Study
- PMID: 29030346
- DOI: 10.1161/CIRCULATIONAHA.117.029457
Diagnostic Accuracy of the Aortic Dissection Detection Risk Score Plus D-Dimer for Acute Aortic Syndromes: The ADvISED Prospective Multicenter Study
Abstract
Background: Acute aortic syndromes (AASs) are rare and severe cardiovascular emergencies with unspecific symptoms. For AASs, both misdiagnosis and overtesting are key concerns, and standardized diagnostic strategies may help physicians to balance these risks. D-dimer (DD) is highly sensitive for AAS but is inadequate as a stand-alone test. Integration of pretest probability assessment with DD testing is feasible, but the safety and efficiency of such a diagnostic strategy are currently unknown.
Methods: In a multicenter prospective observational study involving 6 hospitals in 4 countries from 2014 to 2016, consecutive outpatients were eligible if they had ≥1 of the following: chest/abdominal/back pain, syncope, perfusion deficit, and if AAS was in the differential diagnosis. The tool for pretest probability assessment was the aortic dissection detection risk score (ADD-RS, 0-3) per current guidelines. DD was considered negative (DD-) if <500 ng/mL. Final case adjudication was based on conclusive diagnostic imaging, autopsy, surgery, or 14-day follow-up. Outcomes were the failure rate and efficiency of a diagnostic strategy for ruling out AAS in patients with ADD-RS=0/DD- or ADD-RS ≤1/DD-.
Results: A total of 1850 patients were analyzed. Of these, 438 patients (24%) had ADD-RS=0, 1071 patients (58%) had ADD-RS=1, and 341 patients (18%) had ADD-RS >1. Two hundred forty-one patients (13%) had AAS: 125 had type A aortic dissection, 53 had type B aortic dissection, 35 had intramural aortic hematoma, 18 had aortic rupture, and 10 had penetrating aortic ulcer. A positive DD test result had an overall sensitivity of 96.7% (95% confidence interval [CI], 93.6-98.6) and a specificity of 64% (95% CI, 61.6-66.4) for the diagnosis of AAS; 8 patients with AAS had DD-. In 294 patients with ADD-RS=0/DD-, 1 case of AAS was observed. This yielded a failure rate of 0.3% (95% CI, 0.1-1.9) and an efficiency of 15.9% (95% CI, 14.3-17.6) for the ADD-RS=0/DD- strategy. In 924 patients with ADD-RS ≤1/DD-, 3 cases of AAS were observed. This yielded a failure rate of 0.3% (95% CI, 0.1-1) and an efficiency of 49.9% (95% CI, 47.7-52.2) for the ADD-RS ≤1/DD- strategy.
Conclusions: Integration of ADD-RS (either ADD-RS=0 or ADD-RS ≤1) with DD may be considered to standardize diagnostic rule out of AAS.
Clinical trial registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02086136.
Keywords: aorta; dissection; fibrin fragment D; syndrome.
© 2017 American Heart Association, Inc.
Comment in
-
Biomarker-Assisted Diagnosis of Acute Aortic Dissection.Circulation. 2018 Jan 16;137(3):270-272. doi: 10.1161/CIRCULATIONAHA.117.032048. Circulation. 2018. PMID: 29335286 No abstract available.
-
Letter by Wang and Zhao Regarding Article, "Diagnostic Accuracy of the Aortic Dissection Detection Risk Score Plus D-Dimer for Acute Aortic Syndromes: The ADvISED Prospective Multicenter Study".Circulation. 2018 Jul 24;138(4):447. doi: 10.1161/CIRCULATIONAHA.118.034581. Circulation. 2018. PMID: 30571365 No abstract available.
-
Response by Morello et al to Letters Regarding Article, "Diagnostic Accuracy of the Aortic Dissection Detection Risk Score Plus D-Dimer for Acute Aortic Syndromes: The ADvISED Prospective Multicenter Study".Circulation. 2018 Jul 24;138(4):448-449. doi: 10.1161/CIRCULATIONAHA.118.034861. Circulation. 2018. PMID: 30571366 No abstract available.
-
Letter by Roncon et al Regarding Article, "Diagnostic Accuracy of the Aortic Dissection Detection Risk Score Plus D-Dimer for Acute Aortic Syndromes: The ADvISED Prospective Multicenter Study".Circulation. 2018 Jul 24;138(4):445-446. doi: 10.1161/CIRCULATIONAHA.118.033804. Circulation. 2018. PMID: 30571369 No abstract available.
Similar articles
-
Systematic Review of Aortic Dissection Detection Risk Score Plus D-dimer for Diagnostic Rule-out Of Suspected Acute Aortic Syndromes.Acad Emerg Med. 2020 Oct;27(10):1013-1027. doi: 10.1111/acem.13969. Epub 2020 Apr 21. Acad Emerg Med. 2020. PMID: 32187432
-
Accuracy of a diagnostic strategy combining aortic dissection detection risk score and D-dimer levels in patients with suspected acute aortic syndrome.Eur Heart J Acute Cardiovasc Care. 2017 Aug;6(5):371-378. doi: 10.1177/2048872615594497. Epub 2015 Jul 16. Eur Heart J Acute Cardiovasc Care. 2017. PMID: 26185259
-
Integration of transthoracic focused cardiac ultrasound in the diagnostic algorithm for suspected acute aortic syndromes.Eur Heart J. 2019 Jun 21;40(24):1952-1960. doi: 10.1093/eurheartj/ehz207. Eur Heart J. 2019. PMID: 31226214 Clinical Trial.
-
Accuracy of aortic dissection detection risk score alone or with D-dimer: A systematic review and meta-analysis.Eur Heart J Acute Cardiovasc Care. 2020 Oct;9(3_suppl):S32-S39. doi: 10.1177/2048872620901831. Epub 2020 Jan 23. Eur Heart J Acute Cardiovasc Care. 2020. PMID: 31970996
-
Development and Validation of a Simplified Probability Assessment Score Integrated With Age-Adjusted d-Dimer for Diagnosis of Acute Aortic Syndromes.J Am Heart Assoc. 2021 Feb 2;10(3):e018425. doi: 10.1161/JAHA.120.018425. Epub 2021 Jan 21. J Am Heart Assoc. 2021. PMID: 33474974 Free PMC article.
Cited by
-
Diagnosing acute aortic syndrome: a Canadian clinical practice guideline.CMAJ. 2020 Jul 20;192(29):E832-E843. doi: 10.1503/cmaj.200021. CMAJ. 2020. PMID: 32690558 Free PMC article. No abstract available.
-
Acute aortic syndrome.BMJ. 2024 Sep 17;386:e080870. doi: 10.1136/bmj-2024-080870. BMJ. 2024. PMID: 39288946 Free PMC article. No abstract available.
-
ADAMTS-7 deficiency attenuates thoracic aortic aneurysm and dissection in mice.J Mol Med (Berl). 2023 Mar;101(3):237-248. doi: 10.1007/s00109-023-02284-w. Epub 2023 Jan 20. J Mol Med (Berl). 2023. PMID: 36662289
-
Initial Evaluation and Management of Patients Presenting with Acute Chest Pain in the Emergency Department.Curr Cardiol Rep. 2023 Dec;25(12):1677-1686. doi: 10.1007/s11886-023-01984-6. Epub 2023 Oct 27. Curr Cardiol Rep. 2023. PMID: 37889421 Review.
-
Prognostic value of serum albumin for patients with acute aortic dissection: A retrospective cohort study.Medicine (Baltimore). 2019 Feb;98(6):e14486. doi: 10.1097/MD.0000000000014486. Medicine (Baltimore). 2019. PMID: 30732220 Free PMC article.
Publication types
MeSH terms
Substances
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical