Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2018 Apr;25(2):129-138.
doi: 10.1007/s10140-017-1559-6. Epub 2017 Oct 13.

Does radiography still have a significant diagnostic role in evaluation of acute traumatic wrist injuries? A prospective comparative study

Affiliations
Comparative Study

Does radiography still have a significant diagnostic role in evaluation of acute traumatic wrist injuries? A prospective comparative study

Mohammad Abd Alkhalik Basha et al. Emerg Radiol. 2018 Apr.

Abstract

Aim: The aim of this study was to evaluate and compare the diagnostic role of radiography and multi-detector computed tomography (MDCT) in acute traumatic wrist injuries.

Patients and methods: One hundred sixty-eight patients with acute wrist trauma were enrolled in our study. All patients had submitted to radiography and MDCT within 24 h after wrist trauma. The diagnostic role of radiography and MDCT was evaluated and compared. The effective radiation dose of the two techniques was calculated.

Results: One hundred four (61.9%) and 84 (50%) out of 168 patients had acute wrist injuries on MDCT and radiographic examinations, respectively. Using MDCT results as a reference standard, the sensitivity, specificity, and accuracy of radiography in the diagnosis of distal radius fracture were 85.7, 96, and 92.3%, respectively, and in the diagnosis of scaphoid fracture were 62.5, 97.3, and 88.5%, respectively. As regards detection of acute traumatic wrist injuries, we observed no significant difference between the two modalities (P = 0.1347); in addition, both modalities had high consistency (κ = 0.8359). The mean effective radiation dose of radiography was 0.01 mSv and of MDCT was 0.1 mSv.

Conclusion: Radiography still remains as the first screening tool in acute traumatic wrist injuries and MDCT is complementary to it and used as a problem-solving tool or for preoperative planning.

Keywords: Acute traumatic wrist injuries; MDCT; Radiography.

PubMed Disclaimer

References

    1. Orthop Clin North Am. 1993 Apr;24(2):217-28 - PubMed
    1. Clin Orthop Relat Res. 1980 Jun;(149):9-20 - PubMed
    1. Emerg Radiol. 2004 Feb;10 (4):182-5 - PubMed
    1. AJR Am J Roentgenol. 1987 Jul;149(1):109-11 - PubMed
    1. Radiographics. 2000 Nov-Dec;20(6):1787-806 - PubMed

Publication types

LinkOut - more resources