Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Mar 28;56(4):582-594.
doi: 10.1515/cclm-2017-0648.

Strong impact on plasma protein profiles by precentrifugation delay but not by repeated freeze-thaw cycles, as analyzed using multiplex proximity extension assays

Affiliations

Strong impact on plasma protein profiles by precentrifugation delay but not by repeated freeze-thaw cycles, as analyzed using multiplex proximity extension assays

Qiujin Shen et al. Clin Chem Lab Med. .

Abstract

Background A number of factors regarding blood collection, handling and storage may affect sample quality. The purpose of this study was to assess the impact on plasma protein profiles by delayed centrifugation and plasma separation and multiple freeze-thaw cycles. Methods Blood samples drawn from 16 healthy individuals were collected into ethylenediaminetetraacetic acid tubes and kept either at 4 °C or 22 °C for 1-36 h prior to centrifugation. Plasma samples prepared 1 h after venipuncture were also subjected to two to eight cycles of freezing at -80 °C and thawing at 22 °C. Multiplex proximity extension assay, an antibody-based protein assay, was used to investigate the influence on plasma proteins. Results Up to 36 h delay before blood centrifugation resulted in significant increases of 16 and 40 out of 139 detectable proteins in samples kept at 4 °C or 22 °C, respectively. Some increases became noticeable after 8 h delay at 4 °C but already after 1 h at 22 °C. For samples stored at 4 °C, epidermal growth factor (EGF), NF-kappa-B essential modulator, SRC, interleukin 16 and CD6 increased the most, whereas the five most significantly increased proteins after storage at 22 °C were CD40 antigen ligand (CD40-L), EGF, platelet-derived growth factor subunit B, C-X-C motif chemokine ligand 5 and matrix metallopeptidase 1 (MMP1). Only matrix metallopeptidase 7 (MMP7) decreased significantly over time and only after storage at 22 °C. No protein levels were found to be significantly affected by up to eight freeze-thaw cycles. Conclusions Plasma should be prepared from blood after a limited precentrifugation delay at a refrigerated temperature. By contrast, the influence by several freeze-thaw cycles on detectable protein levels in plasma was negligible.

Keywords: biobank; protein detection; proteome; proximity extension assay (PEA); sample collection and handling.

PubMed Disclaimer

Similar articles

Cited by

References

    1. van Ommen G-J, Törnwall O, Bréchot C, Dagher G, Galli J, Hveem K, et al. BBMRI-ERIC as a resource for pharmaceutical and life science industries: the development of biobank-based Expert Centres. Eur J Hum Genet 2015;23:893–900.
    1. Betsou F, Lehmann S, Ashton G, Barnes M, Benson EE, Coppola D, et al. Standard preanalytical coding for biospecimens; defining the sample PREanalytical code. Cancer Epidemiol Biomarkers Prev 2010;19:1004–11.
    1. Lehmann S, Guadagni F, Moore H, Ashton G, Barnes M, Benson E, et al. Standard preanalytical coding for biospecimens: review and implementation of the sample PREanalytical Code (SPREC). Biopreserv Biobank 2012;10:366–74.
    1. Tuck MK, Chan DW, Chia D, Godwin AK, Grizzle WE, Krueger KE, et al. Standard operating procedures for serum and plasma collection. J Proteome Res 2010;8:113–7.
    1. Rai AJ, Gelfand CA, Haywood BC, Warunek DJ, Yi J, Schuchard MD, et al. HUPO Plasma Proteome Project specimen collection and handling: towards the standardization of parameters for plasma proteome samples. Proteomics 2005;5:3262–77.