Determination of optical properties of turbid medium from relative interstitial CW radiance measurements using the incomplete P3 approximation

Free article

Determination of optical properties of turbid medium from relative interstitial CW radiance measurements using the incomplete P3 approximation

Lingling Liu et al. Opt Express. .
Free article

Abstract

Interstitial determination of the tissue optical properties is important in biomedicine, especially for interstitial laser therapies. Continuous wave (CW) radiance techniques which examine light from multiple directions have been proposed as minimally invasive methods for determining the optical properties under an interstitial probe arrangement. However, both the fitting algorithm based on the P3 approximation and the analytical method based on the diffusion approximation (DA), which are currently used recovery algorithms, cannot extract the optical properties of tissue with low transport albedos accurately from radiance measurements. In this paper, we proposed an incomplete P3 approximation for the radiance, the P3in for short, which is the asymptotic part of the solution for the P3 approximation. The relative differences between the P3in and the P3 were within 0.48% over a wide range of clinically relevant optical properties for measurements at source detector separations (SDS) from 5 mm to 10 mm and angles from 0° to 160°. Based on the P3in, we developed an analytical method for extracting the optical properties directly using simple expressions constructed from the radiance measurements at only two SDSs and four angles. The developed recovery algorithm was verified by simulated and experimental radiance data. The results show that both the absorption and reduced scattering coefficients were recovered accurately with relative errors within 5.28% and 3.86%, respectively, from the simulated data and with relative errors within 10.82% and 10.67%, respectively, from the experimental data over a wide range of albedos from 0.5 to 0.99. Since the developed P3in-based radiance technique can obtain the optical properties rapidly from the measurements at only two SDSs and four angles, it is expected to be used for in vivo and in situ determination of the optical properties in online treatment planning during laser therapies.