Comparison Between Patent Ductus Arteriosus Stent and Modified Blalock-Taussig Shunt as Palliation for Infants With Ductal-Dependent Pulmonary Blood Flow: Insights From the Congenital Catheterization Research Collaborative
- PMID: 29042354
- DOI: 10.1161/CIRCULATIONAHA.117.029987
Comparison Between Patent Ductus Arteriosus Stent and Modified Blalock-Taussig Shunt as Palliation for Infants With Ductal-Dependent Pulmonary Blood Flow: Insights From the Congenital Catheterization Research Collaborative
Abstract
Background: Infants with ductal-dependent pulmonary blood flow may undergo palliation with either a patent ductus arteriosus (PDA) stent or a modified Blalock-Taussig (BT) shunt. A balanced multicenter comparison of these 2 approaches is lacking.
Methods: Infants with ductal-dependent pulmonary blood flow palliated with either a PDA stent or a BT shunt from January 2008 to November 2015 were reviewed from the 4 member centers of the Congenital Catheterization Research Collaborative. Outcomes were compared by use of propensity score adjustment to account for baseline differences between groups.
Results: One hundred six patients with a PDA stent and 251 patients with a BT shunt were included. The groups differed in underlying anatomy (expected 2-ventricle circulation in 60% of PDA stents versus 45% of BT shunts; P=0.001) and presence of antegrade pulmonary blood flow (61% of PDA stents versus 38% of BT shunts; P<0.001). After propensity score adjustment, there was no difference in the hazard of the primary composite outcome of death or unplanned reintervention to treat cyanosis (hazard ratio, 0.8; 95% confidence interval [CI], 0.52-1.23; P=0.31). Other reinterventions were more common in the PDA stent group (hazard ratio, 29.8; 95% CI, 9.8-91.1; P<0.001). However, the PDA stent group had a lower adjusted intensive care unit length of stay (5.3 days [95% CI, 4.2-6.7] versus 9.19 days [95% CI, 7.9-10.6]; P<0.001), a lower risk of diuretic use at discharge (odds ratio, 0.4; 95% CI, 0.25-0.64; P<0.001) and procedural complications (odds ratio, 0.4; 95% CI, 0.2-0.77; P=0.006), and larger (152 mm2/m2 [95% CI, 132-176] versus 125 mm2/m2 [95% CI, 113-138]; P=0.029) and more symmetrical (symmetry index, 0.84 [95% CI, 0.8-0.89] versus 0.77 [95% CI, 0.75-0.8]; P=0.008] pulmonary arteries at the time of subsequent surgical repair or last follow-up.
Conclusions: In this multicenter comparison of palliative PDA stent and BT shunt for infants with ductal-dependent pulmonary blood flow adjusted for differences in patient factors, there was no difference in the primary end point, death or unplanned reintervention to treat cyanosis. However, other markers of morbidity and pulmonary artery size favored the PDA stent group, supporting PDA stent as a reasonable alternative to BT shunt in select patients.
Keywords: Blalock-Taussig procedure; ductus arteriosus, patent; heart diseases; propensity score; stents.
© 2017 American Heart Association, Inc.
Comment in
-
Comparisons Between Ductal Stenting and Blalock-Taussig Shunts for Infants With Ductal-Dependent Pulmonary Circulation.Circulation. 2018 Feb 6;137(6):602-604. doi: 10.1161/CIRCULATIONAHA.117.031998. Circulation. 2018. PMID: 29431661 No abstract available.
-
Letter by Santoro et al Regarding Articles, "Duct Stenting Versus Modified Blalock-Taussig Shunt in Neonates With Duct-Dependent Pulmonary Blood Flow: Associations With Clinical Outcomes in a Multicenter National Study" and "Comparison Between Patent Ductus Arteriosus Stent and Modified Blalock-Taussig Shunt as Palliation for Infants With Ductal-Dependent Pulmonary Blood Flow: Insights From the Congenital Catheterization Research Collaborative".Circulation. 2018 Jul 24;138(4):432-433. doi: 10.1161/CIRCULATIONAHA.118.034410. Circulation. 2018. PMID: 30571362 No abstract available.
-
Response by Glatz et al to Letter Regarding Article, "Comparison Between Patent Ductus Arteriosus Stent and Modified Blalock-Taussig Shunt as Palliation for Infants With Ductal-Dependent Pulmonary Blood Flow: Insights From the Congenital Catheterization Research Collaborative".Circulation. 2018 Jul 24;138(4):436-437. doi: 10.1161/CIRCULATIONAHA.118.035223. Circulation. 2018. PMID: 30571367 No abstract available.
Similar articles
-
Duct Stenting Versus Modified Blalock-Taussig Shunt in Neonates With Duct-Dependent Pulmonary Blood Flow: Associations With Clinical Outcomes in a Multicenter National Study.Circulation. 2018 Feb 6;137(6):581-588. doi: 10.1161/CIRCULATIONAHA.117.028972. Epub 2017 Oct 30. Circulation. 2018. PMID: 29084734
-
Differences in Cost of Care by Palliation Strategy for Infants With Ductal-Dependent Pulmonary Blood Flow.Circ Cardiovasc Interv. 2019 Apr;12(4):e007232. doi: 10.1161/CIRCINTERVENTIONS.118.007232. Circ Cardiovasc Interv. 2019. PMID: 30998390 Free PMC article.
-
Comparison of Outcomes at Time of Superior Cavopulmonary Connection Between Single Ventricle Patients With Ductal-Dependent Pulmonary Blood Flow Initially Palliated With Either Blalock-Taussig Shunt or Ductus Arteriosus Stent: Results From the Congenital Catheterization Research Collaborative.Circ Cardiovasc Interv. 2019 Oct;12(10):e008110. doi: 10.1161/CIRCINTERVENTIONS.119.008110. Epub 2019 Oct 14. Circ Cardiovasc Interv. 2019. PMID: 31607156
-
Blalock-Taussig shunt versus patent ductus arteriosus stent as first palliation for ductal-dependent pulmonary circulation lesions: A review of the literature.Congenit Heart Dis. 2019 Jan;14(1):105-109. doi: 10.1111/chd.12707. Congenit Heart Dis. 2019. PMID: 30811802 Review.
-
Arterial duct stent versus surgical shunt for patients with duct-dependent pulmonary circulation: a meta-analysis.BMC Cardiovasc Disord. 2021 Jan 6;21(1):9. doi: 10.1186/s12872-020-01817-2. BMC Cardiovasc Disord. 2021. PMID: 33407150 Free PMC article.
Cited by
-
Virtual Reality in Neonatal Ductal Stenting: A New Era in Preprocedural Planning for Ductus Arteriosus Stenting in Complex Congenital Heart Defects with Duct-Dependent Pulmonary Circulation.Pediatr Cardiol. 2025 Jun 6. doi: 10.1007/s00246-025-03908-3. Online ahead of print. Pediatr Cardiol. 2025. PMID: 40478297
-
Impact of Drug Elution on Infectious Outcomes after Ductal Stenting in Newborns.Pediatr Cardiol. 2024 Sep 5. doi: 10.1007/s00246-024-03625-3. Online ahead of print. Pediatr Cardiol. 2024. PMID: 39231824
-
Stenting of the Patent Ductus Arteriosus: A Meta-analysis and Literature Review.J Soc Cardiovasc Angiogr Interv. 2022 Jul 7;1(6):100392. doi: 10.1016/j.jscai.2022.100392. eCollection 2022 Nov-Dec. J Soc Cardiovasc Angiogr Interv. 2022. PMID: 39132356 Free PMC article. Review.
-
The ductus arteriosus in neonates with critical congenital heart disease.J Perinatol. 2022 Dec;42(12):1708-1713. doi: 10.1038/s41372-022-01449-8. Epub 2022 Jul 15. J Perinatol. 2022. PMID: 35840708 Review.
-
Axillary Artery Approach for Ductal Stenting in Neonates and Infants.Pediatr Cardiol. 2025 Jun 23. doi: 10.1007/s00246-025-03927-0. Online ahead of print. Pediatr Cardiol. 2025. PMID: 40550951
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical