. 2019 Jun;26(3):899-905.
doi: 10.1007/s12350-017-1086-6. Epub 2017 Oct 17.

Evaluation of left ventricular mass on cadmium-zinc-telluride imaging: Validation against cardiac magnetic resonance

Affiliations

Evaluation of left ventricular mass on cadmium-zinc-telluride imaging: Validation against cardiac magnetic resonance

Alessia Gimelli et al. J Nucl Cardiol. 2019 Jun.

Abstract

Background: Single-photon emission computed tomography has shown relevant limitations in the quantification of left ventricular (LV) mass. We sought to compare the estimates of LV mass on Cadmium-Zinc-Telluride (CZT) myocardial perfusion imaging (MPI) as compared to cardiac magnetic resonance (CMR).

Methods and results: Twenty-five patients underwent MPI on a CZT camera and CMR on a 1.5 T scanner within 12 ± 3 weeks. LV mass was quantified on CZT images using two softwares: 4D-MSPECT (4DM) and Emory Cardiac Toolbox (ECTb). LV mass by CMR was quantified using MASS software (Medis, Leiden, The Netherlands). LV mass values obtained with 4DM and ECTb were highly reproducible [intraclass correlation coefficients .98 (95% CI .97-.99), and .98 (95% CI 0.97-.99), respectively]. The mean LVM mass values were 151 ± 44 g on CMR, 151 ± 43 g with 4DM (P = NS vs CMR), and 157 ± 42 g with ECTb (P < .001 vs CMR; P = .007 vs 4DM) CZT images. There was an excellent correlation between LV mass values between CMR and both 4DM (R2 = .95; P < .001) and ECTb (R2 = .98; P < .001) with narrow limits of agreement (- 13.6% to + 13.4% for 4DM, and - 5.6% to + 14.1% for ECTb).

Conclusions: The evaluation of LV mass is feasible on CZT images, showing excellent agreement with CMR.

Keywords: Cadmium-Zinc-Telluride; SPECT; cardiac magnetic resonance; left ventricular mass.

PubMed Disclaimer

Comment in

Similar articles

Cited by

References

    1. JACC Cardiovasc Imaging. 2012 Nov;5(11):1115-23 - PubMed
    1. J Nucl Cardiol. 2007 Jul;14(4):455-65 - PubMed
    1. J Nucl Cardiol. 2009 Sep-Oct;16(5):775-83 - PubMed
    1. Circulation. 2000 Jul 25;102(4):470-9 - PubMed
    1. Eur Heart J Cardiovasc Imaging. 2018 Mar 1;19(3):299-309 - PubMed

LinkOut - more resources