Correlation of Treponemal Immunoassay Signal Strength Values with Reactivity of Confirmatory Treponemal Testing
- PMID: 29046410
- PMCID: PMC5744207
- DOI: 10.1128/JCM.01165-17
Correlation of Treponemal Immunoassay Signal Strength Values with Reactivity of Confirmatory Treponemal Testing
Abstract
Automated treponemal immunoassays are used for syphilis screening with the reverse-sequence algorithm; discordant results (e.g., enzyme immunoassay [EIA] reactive and reactive plasma reagin [RPR] nonreactive) are resolved with a second treponemal test. We conducted a study to determine automated immunoassay signal strength values consistently correlating with reactive confirmatory treponemal testing. We conducted a cross-sectional analysis of four automated immunoassays (BioPlex 2200 microbead immunoassay [MBIA], Liaison chemiluminescence immunoassay [CIA], Advia-Centaur CIA, and Trep-Sure EIA) and three manual assays (Treponema pallidum particle agglutination [TP-PA], fluorescent treponemal antibody absorption [FTA-ABS] test, and Inno-LIA line immunoassay). We compared signal strength values of automated immunoassays and positive and negative agreement. Among 1,995 specimens, 908 (45.5%) were true positives (≥4/7 tests reactive) and 1,087 (54.5%) were true negatives (≥4/7 tests nonreactive). Positive agreement ranged from 86.1% (83.7 to 88.2%) for FTA-ABS to 99.7% (99.0 to 99.9%) for Advia-Centaur CIA; negative agreement ranged from 86.3% (84.1 to 88.2%) for Trep-Sure EIA to 100% for TP-PA (99.6 to 100%). Increasing signal strength values correlated with increasing reactivity of confirmatory testing (P < 0.0001 for all automated immunoassays by Cochran-Armitage test for trend). All automated immunoassays had signal strength cutoffs corresponding to ≥4/7 reactive treponemal tests. BioPlex MBIA and Liaison CIA had signal strength cutoffs correlating with ≥99% and 100% TP-PA reactivity, respectively. The Advia-Centaur CIA and Trep-Sure EIA had signal strength cutoffs correlating with at least 95% TP-PA reactivity. All automated immunoassays had signal strength cutoffs correlating with at least 95% FTA-ABS reactivity. Assuming that a 95% level of confirmation is adequate, these signal strength values can be used in lieu of confirmatory testing with TP-PA and FTA-ABS.
Keywords: algorithim; automated; immunoassays; syphilis; treponemal.
Similar articles
-
Improvement of reverse sequence algorithm for syphilis diagnosis using optimal treponemal screening assay signal-to-cutoff ratio.PLoS One. 2018 Sep 13;13(9):e0204001. doi: 10.1371/journal.pone.0204001. eCollection 2018. PLoS One. 2018. PMID: 30212544 Free PMC article.
-
Performance of Treponemal Tests for the Diagnosis of Syphilis.Clin Infect Dis. 2019 Mar 5;68(6):913-918. doi: 10.1093/cid/ciy558. Clin Infect Dis. 2019. PMID: 29986091 Free PMC article.
-
Characterization of sera with discordant results from reverse sequence screening for syphilis.Biomed Res Int. 2013;2013:269347. doi: 10.1155/2013/269347. Epub 2012 Dec 27. Biomed Res Int. 2013. PMID: 23509699 Free PMC article.
-
Sensitivity and Specificity of Treponemal-specific Tests for the Diagnosis of Syphilis.Clin Infect Dis. 2020 Jun 24;71(Suppl 1):S13-S20. doi: 10.1093/cid/ciaa349. Clin Infect Dis. 2020. PMID: 32578866 Free PMC article.
-
[Recent Advances in Laboratory Diagnosis of Syphilis].Mikrobiyol Bul. 2023 Jan;57(1):141-155. doi: 10.5578/mb.20239912. Mikrobiyol Bul. 2023. PMID: 36636853 Review. Turkish.
Cited by
-
Data on the Relationships of Signal-To-Cutoff Ratios of Elecsys HIV Antigen/Antibody and Elecsys Syphilis Assays to Subsequent Confirmatory Testing at an Academic Medical Center.Data Brief. 2021 Nov 6;39:107549. doi: 10.1016/j.dib.2021.107549. eCollection 2021 Dec. Data Brief. 2021. PMID: 34820493 Free PMC article.
-
Sexually Transmitted Infections Treatment Guidelines, 2021.MMWR Recomm Rep. 2021 Jul 23;70(4):1-187. doi: 10.15585/mmwr.rr7004a1. MMWR Recomm Rep. 2021. PMID: 34292926 Free PMC article.
-
Improvement of reverse sequence algorithm for syphilis diagnosis using optimal treponemal screening assay signal-to-cutoff ratio.PLoS One. 2018 Sep 13;13(9):e0204001. doi: 10.1371/journal.pone.0204001. eCollection 2018. PLoS One. 2018. PMID: 30212544 Free PMC article.
-
Evaluating the diagnostic accuracy of TpN17 and TmpA recombinant proteins in syphilis detection: a phase II study.Front Microbiol. 2024 Feb 27;15:1348437. doi: 10.3389/fmicb.2024.1348437. eCollection 2024. Front Microbiol. 2024. PMID: 38476951 Free PMC article.
-
Performance of Treponemal Tests for the Diagnosis of Syphilis.Clin Infect Dis. 2019 Mar 5;68(6):913-918. doi: 10.1093/cid/ciy558. Clin Infect Dis. 2019. PMID: 29986091 Free PMC article.
References
-
- Centers for Disease Control and Prevention. 2011. Discordant results from reverse sequence syphilis screening—five laboratories, United States, 2006–2010. MMWR Morb Mortal Wkly Rep 60:133–137. - PubMed
-
- Centers for Disease Control and Prevention. 2008. Syphilis testing algorithms using treponemal tests for initial screening—four laboratories, New York City, 2005–2006. MMWR Morb Mortal Wkly Rep 57:872–875. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical