Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Nov;12(11):2359-2375.
doi: 10.1038/nprot.2017.103. Epub 2017 Oct 19.

Analysis of human cerebrospinal fluid monoamines and their cofactors by HPLC

Affiliations

Analysis of human cerebrospinal fluid monoamines and their cofactors by HPLC

Marta Batllori et al. Nat Protoc. 2017 Nov.

Abstract

The presence of monoamines and their cofactors (the pterins and vitamin B6 (pyridoxal phosphate (PLP))) in human cerebrospinal fluid (CSF) can be used as indicators of the biosynthesis and turnover of dopamine and serotonin in the brain. In addition, abnormalities in the CSF levels of these molecules are associated with various neurological diseases, including genetic diseases leading to dopamine and serotonin deficiency. Here, we provide a set of quantitative high-performance liquid-chromatography (HPLC) approaches to determine CSF levels of monoamines and their cofactors. This protocol describes step-by-step procedures for CSF sample preparation for the analysis of different molecules, HPLC calibration and analysis, and data quantification and interpretation. Unlike plasma/tissue/blood samples, CSF requires minimal sample preparation: in this protocol, only the analysis of PLP requires mixing with trichloroacetic acid to release the protein-bound vitamin, centrifugation, and mixing of the supernatant with phosphate buffer and sodium cyanide for derivatization in alkaline conditions. Monoamines are analyzed by HPLC with coulometric electrochemical detection (ED), pterins are analyzed by HPLC with coupled coulometric electrochemical and fluorescence detection, and PLP is analyzed by HPLC with fluorescence detection. The quantification of all compounds is achieved by external calibration procedures, and internal quality control and standards are analyzed in each run. We anticipate that investigation of dopamine and serotonin disturbances will be facilitated by measurements of these compounds in human CSF and other biological samples. The estimated time for the different procedures primarily depends on the electrochemical detector stabilization. Overnight stabilization of this detector is advised, and, after that step, preanalytical equilibration rarely exceeds 3 h.

PubMed Disclaimer

References

    1. Clin Chim Acta. 1999 Feb;280(1-2):101-11 - PubMed
    1. J Neurosci Methods. 2005 Mar 15;142(1):153-8 - PubMed
    1. Biochem Biophys Res Commun. 2012 Mar 23;419(4):632-7 - PubMed
    1. Anal Biochem. 1980 Feb;102(1):176-88 - PubMed
    1. Clin Chim Acta. 2017 Feb;465:5-10 - PubMed

MeSH terms

LinkOut - more resources