Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis

Affiliations

Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis

Claudio Chamorro et al. Open Med (Wars). .

Abstract

The purpose of the study is to establish absolute reliability and concurrent validity between hand-held dynamometers (HHDs) and isokinetic dynamometers (IDs) in lower extremity peak torque assessment. Medline, Embase, CINAHL databases were searched for studies related to psychometric properties in muscle dynamometry. Studies considering standard error of measurement SEM (%) or limit of agreement LOA (%) expressed as percentage of the mean, were considered to establish absolute reliability while studies using intra-class correlation coefficient (ICC) were considered to establish concurrent validity between dynamometers. In total, 17 studies were included in the meta-analysis. The COSMIN checklist classified them between fair and poor. Using HHDs, knee extension LOA (%) was 33.59%, 95% confidence interval (CI) 23.91 to 43.26 and ankle plantar flexion LOA (%) was 48.87%, CI 35.19 to 62.56. Using IDs, hip adduction and extension; knee flexion and extension; and ankle dorsiflexion showed LOA (%) under 15%. Lower hip, knee, and ankle LOA (%) were obtained using an ID compared to HHD. ICC between devices ranged between 0.62, CI (0.37 to 0.87) for ankle dorsiflexion to 0.94, IC (0.91to 0.98) for hip adduction. Very high correlation were found for hip adductors and hip flexors and moderate correlations for knee flexors/extensors and ankle plantar/dorsiflexors.

Keywords: Lower extremitie; Muscle strength; Reproducibility of results.

PubMed Disclaimer

Conflict of interest statement

Conflict of interest statement: Authors state no conflict of interest

Figures

Figure 1
Figure 1
Flow-chart representation of selection process for manuscripts to be considered within this systematic review

References

    1. Deones V.L., Wiley S.C., Worrell T.. Assessment of quadriceps muscle performance by a hand-held dynamometer and an isokinetic dynamometer. J. Orthop. Sports Phys. Ther. 1994;20:296–301. - PubMed
    1. Trudelle-Jackson E., Jackson A.W., Frankowski C.M., Long K.M., Meske N.B.. Interdevice reliability and validity assessment of the Nicholas Hand-Held Dynamometer. J. Orthop. Sports Phys. Ther. 1994;20:302–306. - PubMed
    1. Li R.C., Jasiewicz J.M., Middleton J., Condie P., Barriskill A.. The development, validity, and reliability of a manual muscle testing device with integrated limb position sensors. Arch. of Phys. Med. Rehabil. 2006;87:411–417. - PubMed
    1. Mayer F., Horstmann T., Kranenberg U., Röcker K., Dickhuth H.. Reproducibility of isokinetic peak torque and angle at peak torque in the shoulder joint. Int. J. Sports Med. 1994;15:S26–31. - PubMed
    1. Kimura I.F., Gulick D.T., Alexander D.M., Takao S.H.. Reliability of peak torque values for concentric and eccentric shoulder internal and external rotation on the Biodex, Kinetic Communicator, and Lido dynamometers. Isokinet. Exerc. Sci. 1996;6:95–99.

LinkOut - more resources