Effect of different power settings of Er,Cr:YSGG laser before or after tribosilicatization on the microshear bond strength between zirconia and two types of cements
- PMID: 29075997
- DOI: 10.1007/s10103-017-2343-2
Effect of different power settings of Er,Cr:YSGG laser before or after tribosilicatization on the microshear bond strength between zirconia and two types of cements
Abstract
The aim of this study was to evaluate the effect of different output powers of Er,Cr:YSGG laser and the association with tribochemical silica coating on the bond strength between zirconia ceramic and two resin cements. One hundred ninety-two zirconia ceramic bars (IPS e-max ZirCAD Ivoclar Vivadent-) were sectioned (6 × 6 × 4 mm), sintered, and randomly divided into 12 groups for each cement system according to the surface treatment (n = 8): C-without treatment (control); R-tribochemical coating + resin cement (control); 2L-laser (2.0 W) + resin cement; 2LR-laser (2.0 W) + tribochemical coating + resin cement; R2L-tribochemical coating + laser (2.0 W) + resin cement; 2.5L-laser (2.5 W) + resin cement; 2.5LR-laser (2.5 W) + tribochemical coating + resin cement; R2.5L-tribochemical coating + laser (2.5 W) + resin cement; 3L-laser (3.0 W) + resin cement; 3LR-laser (3.0 W) + tribochemical coating + resin cement, R3L-tribochemical coating + laser (3.0 W) + resin cement; and RPHO-tribochemical + resin cement + photoactivation (control). After the surface treatment, the respective primers were applied, and resin cements, Multilink N, Ivoclar Vivadent (M), and Panavia F 2.0, Kuraray Medical Inc. (P), were inserted into Tygon molds which were bonded to the zirconia bars. Each specimen received two cements bars. After 24 h of storage in a relative humidity (100%) at 37 °C, they were evaluated by the microshear test speed of 1 mm/min. The microshear values were analyzed by one-way ANOVA and Tukey's test (α = 0.05). ANOVA showed statistically significant differences among the evaluated groups. The highest bond strength was observed in RPHO, which statistically differed from all groups. The lowest bond strength was observed in M2.5L (Multilink N) and in P3LR (Panavia F 2.0). It can be concluded that the lowest power output tested was suitable and showed bond strength values similar to tribochemical silica deposition. The light curing is important to adhesion and the tribosilicatizated surface achieves similar microshear values to untreated surface in absence of light.
Keywords: Bond strength; Laser; Microshear; Zirconia.
Similar articles
-
Effect of different laser surface treatment on microshear bond strength between zirconia ceramic and resin cement.J Investig Clin Dent. 2015 Nov;6(4):294-300. doi: 10.1111/jicd.12105. Epub 2014 Sep 3. J Investig Clin Dent. 2015. PMID: 25187021
-
Effect of Er,Cr:YSGG laser treatment on microshear bond strength of zirconia to resin cement before and after sintering.J Adhes Dent. 2014 Aug;16(4):377-82. doi: 10.3290/j.jad.a32444. J Adhes Dent. 2014. PMID: 25126623
-
Durable bonding to mechanically and/or chemically pre-treated dental zirconia.J Dent. 2013 Feb;41(2):170-9. doi: 10.1016/j.jdent.2012.10.017. Epub 2012 Nov 5. J Dent. 2013. PMID: 23137995 Clinical Trial.
-
Surface modification of zirconia or lithium disilicate-reinforced glass ceramic by laser texturing to increase the adhesion of prosthetic surfaces to resin cements: an integrative review.Clin Oral Investig. 2023 Jul;27(7):3331-3345. doi: 10.1007/s00784-023-05016-z. Epub 2023 Apr 17. Clin Oral Investig. 2023. PMID: 37069409 Free PMC article. Review.
-
An insight into current concepts and techniques in resin bonding to high strength ceramics.Aust Dent J. 2016 Jun;61(2):163-73. doi: 10.1111/adj.12365. Aust Dent J. 2016. PMID: 26268746 Review.
Cited by
-
Effect of Fiber Laser Irradiation on the Shear Bond Strength between Acrylic Resin and Titanium.Scanning. 2019 Sep 3;2019:5452919. doi: 10.1155/2019/5452919. eCollection 2019. Scanning. 2019. PMID: 31531156 Free PMC article.
-
Effect of laser irradiation on bond strength between zirconia and resin cement or veneer ceramic: A systematic review and meta-analysis.J Indian Prosthodont Soc. 2021 Apr-Jun;21(2):125-137. doi: 10.4103/jips.jips_590_20. J Indian Prosthodont Soc. 2021. PMID: 33938862 Free PMC article.
-
Effects of different frequencies of Er:YAG laser on the bonding properties of zirconia ceramic.Lasers Med Sci. 2022 Dec 20;38(1):4. doi: 10.1007/s10103-022-03660-7. Lasers Med Sci. 2022. PMID: 36538140
-
Surface roughness and characteristics of CAD/CAM zirconia and glass ceramics after combined treatment procedures.BMC Oral Health. 2022 Nov 23;22(1):524. doi: 10.1186/s12903-022-02389-7. BMC Oral Health. 2022. PMID: 36419112 Free PMC article.
-
What Is the Most Effective Technique for Bonding Brackets on Ceramic-A Systematic Review and Meta-Analysis.Bioengineering (Basel). 2022 Jan 3;9(1):14. doi: 10.3390/bioengineering9010014. Bioengineering (Basel). 2022. PMID: 35049723 Free PMC article. Review.
References
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources