Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Feb;40(1):76-83.
doi: 10.1097/FTD.0000000000000445.

Plasma 7-Hydroxymethotrexate Levels Versus Methotrexate to Predict Delayed Elimination in Children Receiving High-Dose Methotrexate

Affiliations

Plasma 7-Hydroxymethotrexate Levels Versus Methotrexate to Predict Delayed Elimination in Children Receiving High-Dose Methotrexate

Nicolas Fabresse et al. Ther Drug Monit. 2018 Feb.

Abstract

Background: The aim of this study was to investigate the correlation between 7-hydroxymethotrexate (7-OHMTX) and creatinine and to evaluate the predictive value of 7-OHMTX levels on delayed elimination at 24 and 48 hours. In addition, differences in methotrexate (MTX), 7-OHMTX levels, and MTX metabolism using the ratio MTX/7-OHMTX were determined according to age.

Methods: The authors included a total of 106 cycles, corresponding to 33 patients (mean age: 9.8 years, range: 2-18 years) suffering from acute lymphoblastic leukemia, non-Hodgkin lymphoma and osteosarcoma and receiving high-dose MTX (HD-MTX). Plasma MTX, 7-OHMTX, and creatinine at T24 and T48 hours were measured.

Results: Children older than 14 years had significantly higher MTX levels at T48 hours (1.25 versus 0.5 μmol/L, P < 0.05) and a higher MTX/7-OHMTX ratio (0.63 versus 0.20, P < 0.05) than children younger than 6 years. Plasma 7-OHMTX at T24 and T48 hours was positively correlated with serum creatinine and creatinine ratio at T24 and T48 hours. MTX levels provided a better specificity and sensitivity at both 24 and 48 hours than 7-OHMTX to predict delayed MTX elimination. A MTX threshold close to 0.83 μmol/L at T48 hours improved specificity from 58% to 82% and keeps sensitivity at 100%. The authors identified a cut-off at 65 μmol/L for MTX at T24 hours with a good sensitivity (75%) and specificity above 50%.

Conclusions: These results confirm the concentration-dependent nephrotoxicity of 7-OHMTX. Children older than 14 years old had a higher MTX levels at 48 hours and a higher MTX/7-OHMTX ratio, suggesting a faster metabolism in younger children. This study identified a higher and more specific MTX threshold at T48 hours compared to those currently used, and a new threshold at T24 hours.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources