Tissue Doppler assessment of diastolic function and relationship with mortality in critically ill septic patients: a systematic review and meta-analysis
- PMID: 29121301
- DOI: 10.1093/bja/aex254
Tissue Doppler assessment of diastolic function and relationship with mortality in critically ill septic patients: a systematic review and meta-analysis
Abstract
Background: Myocardial dysfunction may contribute to circulatory failure in sepsis. There is growing evidence of an association between left ventricular diastolic dysfunction (LVDD) and mortality in septic patients. Utilizing echocardiography, we know that tissue Doppler imaging (TDI) variables e' and E/e' are reliable predictors of LVDD and are useful measurements to estimate left ventricular (LV) filling pressures.
Methods: We conducted a systematic review and meta-analysis to investigate the association of e' and E/e' with mortality of patients with severe sepsis or septic shock. In the primary analysis, we included studies providing transthoracic TDI data for e' and E/e' and their association with mortality. Subgroup analyses were conducted according to myocardial regional focus of TDI assessment (septal, lateral or averaged). Three secondary analyses were performed: one included data from a transoesophageal study, another excluded studies reporting data at a very early (<6 h) or late (>48 h) stage following diagnosis, and the third pooled data only from studies excluding patients with heart valve disease.
Results: The primary analysis included 16 studies with 1507 patients with severe sepsis and/or septic shock. A significant association was found between mortality and both lower e' [standard mean difference (SMD) 0.33; 95% confidence interval (CI): 0.05, 0.62; P=0.02] and higher E/e' (SMD -0.33; 95% CI: -0.57, -0.10; P=0.006). In the subgroup analyses, only the lateral TDI values showed significant association with mortality (lower e' SMD 0.45; 95% CI: 0.11, 0.78; P=0.009; higher E/e' SMD -0.49; 95% CI: -0.76, -0.22; P=0.0003). The findings of the primary analysis were confirmed by all secondary analyses.
Conclusions: There is a strong association between both lower e' and higher E/e' and mortality in septic patients.
Keywords: diastolic dysfunction; echocardiography; intensive care; septic shock; severe sepsis.
© The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Similar articles
-
Detecting impaired myocardial relaxation in sepsis with a novel tissue Doppler parameter (septal e'/s').Crit Care. 2017 Jul 14;21(1):175. doi: 10.1186/s13054-017-1727-9. Crit Care. 2017. PMID: 28705247 Free PMC article.
-
Impact of New-Onset Left Ventricular Dysfunction on Outcomes in Mechanically Ventilated Patients With Severe Sepsis and Septic Shock.J Intensive Care Med. 2018 Dec;33(12):680-686. doi: 10.1177/0885066616684774. Epub 2016 Dec 21. J Intensive Care Med. 2018. PMID: 28553776
-
Improvement of left ventricular relaxation as assessed by tissue Doppler imaging in fluid-responsive critically ill septic patients.Intensive Care Med. 2012 Sep;38(9):1461-70. doi: 10.1007/s00134-012-2618-9. Epub 2012 Jun 21. Intensive Care Med. 2012. PMID: 22717694
-
Left ventricular systolic function evaluated by strain echocardiography and relationship with mortality in patients with severe sepsis or septic shock: a systematic review and meta-analysis.Crit Care. 2018 Aug 4;22(1):183. doi: 10.1186/s13054-018-2113-y. Crit Care. 2018. PMID: 30075792 Free PMC article.
-
Systolic dysfunction as evaluated by tissue Doppler imaging echocardiography and mortality in septic patients: A systematic review and meta-analysis.J Crit Care. 2021 Apr;62:256-264. doi: 10.1016/j.jcrc.2020.12.026. Epub 2020 Dec 31. J Crit Care. 2021. PMID: 33461118
Cited by
-
Prevalence and prognosis of hyperdynamic left ventricular systolic function in septic patients: a systematic review and meta-analysis.Ann Intensive Care. 2024 Feb 3;14(1):22. doi: 10.1186/s13613-024-01255-9. Ann Intensive Care. 2024. PMID: 38308701 Free PMC article.
-
Assessing Fluid Intolerance with Doppler Ultrasonography: A Physiological Framework.Med Sci (Basel). 2022 Feb 9;10(1):12. doi: 10.3390/medsci10010012. Med Sci (Basel). 2022. PMID: 35225945 Free PMC article. Review.
-
Early echocardiographic assessment of cardiac function may be prognostically informative in unresuscitated patients with sepsis: A prospective observational study.PLoS One. 2022 Jul 8;17(7):e0269814. doi: 10.1371/journal.pone.0269814. eCollection 2022. PLoS One. 2022. PMID: 35802886 Free PMC article.
-
Systematic review and literature appraisal on methodology of conducting and reporting critical-care echocardiography studies: a report from the European Society of Intensive Care Medicine PRICES expert panel.Ann Intensive Care. 2020 Apr 25;10(1):49. doi: 10.1186/s13613-020-00662-y. Ann Intensive Care. 2020. PMID: 32335780 Free PMC article. Review.
-
Cardiac Metabolism in Sepsis.Metabolites. 2021 Dec 6;11(12):846. doi: 10.3390/metabo11120846. Metabolites. 2021. PMID: 34940604 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical