Effect of imaging frequency on PTV margins and geographical miss during image guided radiation therapy for prostate cancer
- PMID: 29122556
- DOI: 10.1016/j.prro.2017.09.010
Effect of imaging frequency on PTV margins and geographical miss during image guided radiation therapy for prostate cancer
Abstract
Background: The relationship between frequency of imaging during image guided radiation therapy (IGRT) and planning target volume (PTV) margin remains unclear. This issue is of practical significance given resource and time intensive nature of IGRT. The purpose of this study was to evaluate PTV margins with predefined and commonly used less-than-daily IGRT schedules using data obtained from patients treated with daily IGRT for prostate cancer.
Methods and materials: Daily setup error and 3-dimensional daily alignment data for a total of 108 consecutive patients with prostate cancer treated with 2700 fractions of daily image guidance on tomotherapy were retrospectively analyzed. Five IGRT scenarios were simulated: alternate day, twice weekly, once weekly, first 3 days only, and no image guidance. The daily alignment data were modeled to simulate the 5 predefined scenarios by applying appropriate corrections to determine the PTV margin for each image guidance scenario. The data were also analyzed to predict possible geographical miss in any direction using 2 frequently used PTV margins of 7 and 5 mm for all the scenarios.
Results: Decreasing the frequency of image guidance increased the mean systematic error and the standard deviation of the systematic error. With decreased image guidance frequency, an increase in PTV margins was required to achieve adequate coverage of the clinical target volume. With reduction in image guidance from 50% to 12%, a gradual increase in percentage of fractions with predicted geographical miss using an isotropic PTV margin of 7 or 5 mm was seen. With every 15% decrease in imaging, a 5% increased risk of geographical miss was estimated.
Conclusions: The use of less-than-daily IGRT requires larger PTV margins for patients treated with intensity modulated radiation therapy for prostate cancer. With every 15% reduction, a 5% increased risk of geographical miss was estimated.
Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Inter- and intrafraction uncertainty in prostate bed image-guided radiotherapy.Int J Radiat Oncol Biol Phys. 2012 Oct 1;84(2):402-7. doi: 10.1016/j.ijrobp.2011.12.035. Epub 2012 Feb 28. Int J Radiat Oncol Biol Phys. 2012. PMID: 22381905
-
Evaluating the Need for Daily Image Guidance in Head and Neck Cancers Treated with Helical Tomotherapy: A Retrospective Analysis of a Large Number of Daily Imaging-based Corrections.Clin Oncol (R Coll Radiol). 2016 Mar;28(3):178-84. doi: 10.1016/j.clon.2015.11.014. Epub 2015 Dec 30. Clin Oncol (R Coll Radiol). 2016. PMID: 26746002
-
Image-guided intensity-modulated radiotherapy of prostate cancer: Analysis of interfractional errors and acute toxicity.Strahlenther Onkol. 2016 Feb;192(2):109-17. doi: 10.1007/s00066-015-0919-y. Epub 2015 Nov 6. Strahlenther Onkol. 2016. PMID: 26545764 Free PMC article.
-
ESTRO ACROP consensus guideline on the use of image guided radiation therapy for localized prostate cancer.Radiother Oncol. 2019 Dec;141:5-13. doi: 10.1016/j.radonc.2019.08.027. Epub 2019 Oct 23. Radiother Oncol. 2019. PMID: 31668515
-
[Image guided radiation therapy for prostate cancer; how, when and why?].Cancer Radiother. 2018 Oct;22(6-7):586-592. doi: 10.1016/j.canrad.2018.06.010. Epub 2018 Aug 9. Cancer Radiother. 2018. PMID: 30100124 Review. French.
Cited by
-
Estimation of planning organ at risk volumes for ocular structures in dogs undergoing three-dimensional image-guided periocular radiotherapy with rigid bite block immobilization.Vet Radiol Ultrasound. 2021 Mar;62(2):246-254. doi: 10.1111/vru.12955. Epub 2021 Jan 18. Vet Radiol Ultrasound. 2021. PMID: 33460237 Free PMC article.
-
Robustness Analysis for External Beam Radiation Therapy Treatment Plans: Describing Uncertainty Scenarios and Reporting Their Dosimetric Consequences.Pract Radiat Oncol. 2019 Jul-Aug;9(4):200-207. doi: 10.1016/j.prro.2018.12.002. Epub 2018 Dec 15. Pract Radiat Oncol. 2019. PMID: 30562614 Free PMC article. Review.
-
Automated algorithm for calculation of setup corrections and planning target volume margins for offline image-guided radiotherapy protocols.J Appl Clin Med Phys. 2021 Jul;22(7):137-146. doi: 10.1002/acm2.13291. Epub 2021 Jun 9. J Appl Clin Med Phys. 2021. PMID: 34109736 Free PMC article.
-
Forecasting of the composite dose for organs at risk and solid targets with random movements during different image-guided scenarios of the photon radiation therapy. Solution for the Varian therapeutic line.Rep Pract Oncol Radiother. 2021 Jun 9;26(3):489-494. doi: 10.5603/RPOR.a2021.0051. eCollection 2021. Rep Pract Oncol Radiother. 2021. PMID: 34277106 Free PMC article.
-