Optimal Line and Tube Placement in Very Preterm Neonates: An Audit of Practice
- PMID: 29149032
- PMCID: PMC5704133
- DOI: 10.3390/children4110099
Optimal Line and Tube Placement in Very Preterm Neonates: An Audit of Practice
Abstract
Background: Placement of endotracheal tubes (ETTs) and umbilical catheters (UCs) is essential in very preterm infant care. The aim of this study was to assess the effect of an educational initiative to optimize correct placement of ETTs and UCs in very preterm infants.
Methods: A pre-post study design, evaluating optimal radiological position of ETTs and UCs in the first 72 h of life in infants <32 weeks gestational age (GA) was performed. Baseline data was obtained from a preceding 34-month period. The study intervention consisted of information from the pre-intervention audit, surface anatomy images of the newborn for optimal UC positioning, and weight-based calculations to estimate insertion depths for endotracheal intubation. A prospective evaluation of radiological placement of ETTs and UCs was then conducted over a 12-month period.
Results: During the study period, 211 infants had at least one of the three procedures performed. One hundred and fifty-seven infants were included in the pre-education group, and 54 in the post-education group. All three procedures were performed in 50.3% (79/157) in the pre-education group, and 55.6% (30/54) in the post-education group. There was no significant difference in accurate placement following the introduction of the educational sessions; depth of ETTs (50% vs. 47%), umbilical arterial catheter (UAC) (40% vs. 43%,), and umbilical venous catheter (UVC)(14% vs. 23%).
Conclusion: Despite education of staff on methods for appropriate ETT, UVC and UAC insertion length, the rate of accurate initial insertion depth remained suboptimal. Newer methods of determining optimal position need to be evaluated.
Keywords: neonatal; newborn intubation; preterm infant; umbilical arterial catheter; umbilical venous catheter.
Conflict of interest statement
The authors have no conflicts of interest relevant to this article to disclose.
Figures
Similar articles
-
Standardized endotracheal tube and intravascular access placement in infants born at 22-23 weeks gestation.Pediatr Res. 2025 Jun 18. doi: 10.1038/s41390-025-04186-8. Online ahead of print. Pediatr Res. 2025. PMID: 40533504
-
Estimating umbilical catheter insertion depth in newborns using weight or body measurement: a randomised trial.Arch Dis Child Fetal Neonatal Ed. 2016 Jan;101(1):F10-5. doi: 10.1136/archdischild-2014-307668. Epub 2015 Aug 11. Arch Dis Child Fetal Neonatal Ed. 2016. PMID: 26265678 Clinical Trial.
-
Accuracy of 11 formulae to guide umbilical arterial catheter tip placement in newborn infants.Arch Dis Child Fetal Neonatal Ed. 2018 Jul;103(4):F364-F369. doi: 10.1136/archdischild-2017-313039. Epub 2017 Aug 17. Arch Dis Child Fetal Neonatal Ed. 2018. PMID: 28818852
-
Standardizing umbilical catheter usage in preterm infants.Pediatrics. 2014 Jun;133(6):e1742-52. doi: 10.1542/peds.2013-1373. Epub 2014 May 19. Pediatrics. 2014. PMID: 24843063
-
Evaluation of umbilical catheter and tube placement in premature infants.Radiographics. 1991 Sep;11(5):849-63. doi: 10.1148/radiographics.11.5.1947320. Radiographics. 1991. PMID: 1947320 Review.
Cited by
-
Standardized endotracheal tube and intravascular access placement in infants born at 22-23 weeks gestation.Pediatr Res. 2025 Jun 18. doi: 10.1038/s41390-025-04186-8. Online ahead of print. Pediatr Res. 2025. PMID: 40533504
-
Proper Depth of Percutaneous Central Venous Catheter via the Great Saphenous Vein for Very Low Birth Weight Infants: A Single-Center, Prospective Cohort Study.J Korean Med Sci. 2023 Jan 30;38(4):e23. doi: 10.3346/jkms.2023.38.e23. J Korean Med Sci. 2023. PMID: 36718560 Free PMC article.
-
Umbilical Venous Catheters and Peripherally Inserted Central Catheters: Are They Equally Safe in VLBW Infants? A Non-Randomized Single Center Study.Medicina (Kaunas). 2019 Aug 6;55(8):442. doi: 10.3390/medicina55080442. Medicina (Kaunas). 2019. PMID: 31390790 Free PMC article.
-
Automatic Catheter and Tube Detection in Pediatric X-ray Images Using a Scale-Recurrent Network and Synthetic Data.J Digit Imaging. 2020 Feb;33(1):181-190. doi: 10.1007/s10278-019-00201-7. J Digit Imaging. 2020. PMID: 30972586 Free PMC article.
-
Inadvertent Migration of Umbilical Venous Catheters Often Leads to Malposition.Neonatology. 2019;115(3):205-210. doi: 10.1159/000494369. Epub 2019 Jan 15. Neonatology. 2019. PMID: 30645997 Free PMC article.
References
-
- Schmolzer G.M., Roehr C.C. Techniques to ascertain correct endotracheal tube placement in neonates. Cochrane Database Syst. Rev. 2014;9:CD010221. - PubMed
-
- Korver A.M., Walther F.J., van der Molen A.J., de Beaufort A.J. Serious complications of umbilical venous catheterisation. Nederlands Tijdschrift Voor Geneeskunde. 2007;151:2219–2223. - PubMed
LinkOut - more resources
Full Text Sources
Other Literature Sources