Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2018 Feb;27(2):242-251.
doi: 10.1016/j.jse.2017.08.023. Epub 2017 Nov 20.

Radiologic and clinical evaluation of a bioabsorbable collagen implant to treat partial-thickness tears: a prospective multicenter study

Affiliations
Randomized Controlled Trial

Radiologic and clinical evaluation of a bioabsorbable collagen implant to treat partial-thickness tears: a prospective multicenter study

Theodore F Schlegel et al. J Shoulder Elbow Surg. 2018 Feb.

Abstract

Background: Treatment of partial-thickness cuff tears remains controversial. Although conservative therapy may treat symptoms, these defects do not spontaneously heal and conversion to a full-thickness lesion with subsequent repair may alter the tendon footprint. The ability to induce new tissue formation and limit tear progression in intermediate- and high-grade partial-thickness tears without surgical repair may represent a significant advancement in the treatment paradigm for these lesions.

Methods: We prospectively enrolled 33 patients with chronic, degenerative, intermediate-grade (n = 12) or high-grade (n = 21) partial-thickness tears (11 articular, 10 bursal, 4 intrasubstance, and 8 hybrid) of the supraspinatus tendon in a multicenter study. Following arthroscopic subacromial decompression without repair, a bioinductive implant was attached over the bursal surface of the tendon. Clinical outcomes were assessed using American Shoulder and Elbow Surgeons and Constant-Murley scores preoperatively and at 3 and 12 months postoperatively. Magnetic resonance imaging was performed to assess postoperative tendon healing and thickness at the original tear site.

Results: At 1-year follow-up, clinical scores improved significantly (P <.0001) and the mean tendon thickness increased by 2.0 mm (P <.0001). Magnetic resonance imaging evidence of complete healing was found in 8 patients and a considerable reduction in defect size was shown in 23, whereas 1 lesion remained stable. In 1 noncompliant patient with a high-grade articular lesion, progression to a full-thickness tear occurred while shoveling snow 1 month after surgery. No serious adverse events related to the implant were reported.

Conclusions: Arthroscopic implantation of a bioinductive collagen scaffold is a safe and effective treatment for intermediate- to high-grade partial-thickness rotator cuff tears of the supraspinatus tendon.

Keywords: Arthroscopy; biological augmentation; collagen implant; magnetic resonance imaging; partial-thickness; rotator cuff tear; shoulder; tissue induction.

PubMed Disclaimer

Publication types