Review
. 2018 Apr;28(4):1709-1718.
doi: 10.1007/s00330-017-5149-5. Epub 2017 Nov 21.

Comparison of gradient-recalled echo and spin-echo echo-planar imaging MR elastography in staging liver fibrosis: a meta-analysis

Affiliations
Review

Comparison of gradient-recalled echo and spin-echo echo-planar imaging MR elastography in staging liver fibrosis: a meta-analysis

Yong Seek Kim et al. Eur Radiol. 2018 Apr.

Abstract

Objectives: To compare the diagnostic performance of gradient-recalled echo-based magnetic resonance elastography (GRE-MRE) and spin-echo echo-planar imaging-based MRE (SE-EPI-MRE) in liver fibrosis staging.

Methods: A systematic literature search was performed to identify studies involving the performance of MRE for the diagnosis of liver fibrosis. Pooled sensitivity, specificity, positive and negative likelihood ratios, the diagnostic odds ratio, and a summary receiver operating characteristic (ROC) curve were estimated by using a bivariate random effects model. Subgroup analyses were performed between different study characteristics.

Results: Twenty-six studies with a total of 3,200 patients were included in the meta-analysis. Pooled sensitivity and specificity of GRE-MRE and SE-EPI-MRE did not differ significantly. The area under the summary ROC curve for stage diagnosis of any (F ≥ 1), significant (F ≥ 2), advanced (F ≥ 3), and cirrhosis (F = 4) on GRE-MRE and SE-EPI-MRE were 0.93 versus 0.94, 0.95 versus 0.94, 0.94 versus 0.95, and 0.92 versus 0.93, respectively. Substantial heterogeneity was detected for both sequences.

Conclusion: Both GRE and SE-EPI-MRE show high sensitivity and specificity for detection of each stage of liver fibrosis, without significant differences. Magnetic resonance elastography (MRE) may be useful for noninvasive evaluation of liver fibrosis in chronic liver disease.

Key points: • Pooled sensitivity and specificity of GRE-MRE and SE-EPI-MRE did not differ significantly. • GRE-MRE and SE-EPI-MRE were highly accurate for detecting all stages of fibrosis. • Due to better agreement and repeatability, GRE-MRE should be used first. • In case of failure on GRE-MRE, SE-EPI-MRE should be used.

Keywords: Fibrosis; Gradient-recalled echo; Magnetic resonance elastography; Meta-analysis; Spin-echo echo-planar.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Korean J Radiol. 2015 Nov-Dec;16(6):1175-87 - PubMed
    1. Gastroenterology. 2008 Jul;135(1):32-40 - PubMed
    1. Radiology. 2014 Oct;273(1):88-98 - PubMed
    1. Invest Radiol. 2013 Aug;48(8):607-13 - PubMed
    1. Radiology. 2017 Mar;282(3):761-770 - PubMed

MeSH terms

LinkOut - more resources