. 2017 Dec 1;29(4):269-275.
doi: 10.5792/ksrr.17.032.

Comparison of an Accelerometer-Based Portable Navigation System, Patient-Specific Instrumentation, and Conventional Instrumentation for Femoral Alignment in Total Knee Arthroplasty

Affiliations

Comparison of an Accelerometer-Based Portable Navigation System, Patient-Specific Instrumentation, and Conventional Instrumentation for Femoral Alignment in Total Knee Arthroplasty

Kohei Kawaguchi et al. Knee Surg Relat Res. .

Abstract

Purpose: The KneeAlign2 (KA2, OrthoAlign Inc.) accelerometer-based portable navigation system and patient-specific instrumentation (PSI; Signature, ZimmerBiomet) are widely used for ideal femoral component alignment in total knee arthroplasty (TKA). However, there has been no comparative study of the KA2 system, PSI, and conventional intramedullary instrumentation (CON). The purpose of this study was to compare the accuracy in achieving proper femoral component alignment and clinical features by using the KA2 navigation system, PSI, and CON.

Materials and methods: We retrospectively compared the accuracy of femoral component alignment of 34 TKAs performed with the KA2 system for implantation of the femoral component, 32 TKAs with PSI, and 33 TKAs with CON.

Results: In the coronal plane, use of the KA2 system was more likely to result in optimal femoral component alignment than the CON and PSI (p<0.01). In the sagittal plane, use of the KA2 system was more likely to result in optimal component alignment than PSI, but the difference between the KA2 and CON was insignificant.

Conclusions: The portable accelerometer-based KA2 navigation system enabled ideal femoral implantation in the coronal and sagittal planes, as compared to the PSI or CON.

Keywords: Arthroplasty; Femoral component alignment; Knee; Navigation; Patient-specific instrumentation.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest

No potential conflict of interest relevant to this article was reported.

Figures

Fig. 1
Fig. 1
(A) Anterioposterior radiograph of the entire lower limb after total knee arthroplasty. (B) Lateral radiograph of the knee. CFA: coronal femoral angle, HKA: hip-knee-ankle angle, CTA: coronal tibial angle, SFA: sagittal femoral angle, STA: sagittal tibial angle.

Similar articles

Cited by

References

    1. Matsuda S, Kawahara S, Okazaki K, Tashiro Y, Iwamoto Y. Postoperative alignment and ROM affect patient satisfaction after TKA. Clin Orthop Relat Res. 2013;471:127–33. doi: 10.1007/s11999-012-2533-y. - DOI - PMC - PubMed
    1. Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA. The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am. 2011;93:1588–96. doi: 10.2106/JBJS.J.00772. - DOI - PubMed
    1. Kim SJ, MacDonald M, Hernandez J, Wixson RL. Computer assisted navigation in total knee arthroplasty: improved coronal alignment. J Arthroplasty. 2005;20(7 Suppl 3):123–31. doi: 10.1016/j.arth.2005.05.003. - DOI - PubMed
    1. Moon YW, Han JH, Lee KH, Jang SW, Seo JG. Clinical outcome of IM-guided total knee arthroplasty with inappropriate femoral resection in coronal plane. Knee Surg Relat Res. 2013;25:19–24. doi: 10.5792/ksrr.2013.25.1.19. - DOI - PMC - PubMed
    1. Rosenberger RE, Hoser C, Quirbach S, Attal R, Hennerbichler A, Fink C. Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2008;16:249–57. doi: 10.1007/s00167-007-0420-y. - DOI - PubMed

LinkOut - more resources