Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1989 Jan;24(1):37-46.
doi: 10.1097/00004424-198901000-00010.

Rapid, contrast-enhanced, diuretic magnetic resonance imaging of unilateral partial ureteral obstruction. An experimental study in micropigs

Affiliations

Rapid, contrast-enhanced, diuretic magnetic resonance imaging of unilateral partial ureteral obstruction. An experimental study in micropigs

A A Tzika et al. Invest Radiol. 1989 Jan.

Abstract

The value of rapid, contrast-enhanced, diuretic magnetic resonance (MR) imaging (using ferrioxamine B and furosemide) in demonstrating partial unilateral ureteral obstruction and the potential of such MR imaging in differentiating obstructive from nonobstructive hydronephrosis was assessed in six micropigs. MR imaging (0.35 Tesla, partial-flip technique with repetition time [TR] of 125 milliseconds, echo-delay time [TE] of 20 milliseconds, and flip angle of 70 degrees) was performed before, and at 5, 12, and 19 days after partial ureteral obstruction. Additionally, MR images were acquired 5, 12, and 19 days after release of obstruction. The diuretic was injected 10 minutes after the contrast medium. MR findings were correlated with results from nuclear scintigraphy (99mTc-DMSA uptake). MR images provided good morphologic detail from which renal size, parenchymal thickness, and degree of hydronephrosis could be determined. Contrast medium allowed assessment of cortical uptake and urinary excretion. The course of cortical signal enhancement best characterized the difference between obstructive and nonobstructive hydronephrosis. Normal kidneys and kidneys with nonobstructive hydronephrosis showed progressive decrease in cortical signal enhancement (-11.7% within 40 minutes) after furosemide injection. The kidneys with obstructive hydronephrosis demonstrated a plateau of signal enhancement without decrease (-0.7% within 40 minutes). These results demonstrate the utility of rapid contrast-enhancing, diuretic MR imaging in differentiating obstructive from nonobstructive hydronephrosis.

PubMed Disclaimer

Publication types

LinkOut - more resources