A technical note on diluting semen for the haemocytometric determination of sperm concentration
- PMID: 2918069
- DOI: 10.1093/oxfordjournals.humrep.a136865
A technical note on diluting semen for the haemocytometric determination of sperm concentration
Abstract
A comparison was made of the use of either an SMI positive displacement pipette or an Eppendorf Varipette as the method of sampling 63 liquefied semen samples for volumetric dilution and haemocytometry to determine sperm concentration. The 95% range of the differences between the values obtained using the SMI and the Varipette with whole tips was from -46.9 to 63.8 x 10(6)/ml. With the Varipette tips cut off 12.5 mm from the end the 95% range was from -52.4 to 55.8 x 10(6)/ml. Previous work had shown that the 95% ranges of differences between duplicate determinations using the SMI pipette were from -7.2 to 6.9 x 10(6)/ml for two 1 + 19 dilutions, or from -16.0 to 12.1 x 10(6)/ml for 1 + 19 and 1 + 49 parallel dilutions. Therefore, since the Varipette had a far greater potential for error, a positive displacement pipette should be used when taking precise volume aliquots of human semen.
Similar articles
-
Standardization and quality control of sperm concentration and sperm motility counts in semen analysis.Hum Reprod. 1986 Aug;1(5):299-303. doi: 10.1093/oxfordjournals.humrep.a136409. Hum Reprod. 1986. PMID: 3558773
-
[Use of Makler counting chamber in semen analysis].Hinyokika Kiyo. 1988 Nov;34(11):1931-3. Hinyokika Kiyo. 1988. PMID: 3242367 Japanese.
-
A new method for rapid determination of sperm concentration in turkey semen.Poult Sci. 1996 Jun;75(6):785-9. doi: 10.3382/ps.0750785. Poult Sci. 1996. PMID: 8737845
-
Evaluation of the semi-automated Autosperm semen analysis system. I. Accuracy and comparison with the conventional method and the automated Hamilton-Thorn system.Fertil Steril. 1990 Jan;53(1):111-9. Fertil Steril. 1990. PMID: 2295329
-
[Advances in standardization and quality control for the analysis of sperm quality parameters].Zhonghua Nan Ke Xue. 2007 Nov;13(11):963-8. Zhonghua Nan Ke Xue. 2007. PMID: 18077904 Review. Chinese.
Cited by
-
Decreasing quality of semen.BMJ. 1992 Nov 14;305(6863):1228-9. doi: 10.1136/bmj.305.6863.1228-c. BMJ. 1992. PMID: 1467744 Free PMC article. No abstract available.
-
Dotette: Programmable, high-precision, plug-and-play droplet pipetting.Biomicrofluidics. 2018 May 21;12(3):034107. doi: 10.1063/1.5030629. eCollection 2018 May. Biomicrofluidics. 2018. PMID: 29861810 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources