Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2018 May;28(5):2077-2088.
doi: 10.1007/s00330-017-5152-x. Epub 2017 Nov 30.

Contrast-enhanced US for characterization of focal liver lesions: a comprehensive meta-analysis

Affiliations
Review

Contrast-enhanced US for characterization of focal liver lesions: a comprehensive meta-analysis

Menglin Wu et al. Eur Radiol. 2018 May.

Abstract

Objectives: This meta-analysis was performed to evaluate the accuracy of contrast-enhanced ultrasound (CEUS) in differentiating malignant from benign focal liver lesions (FLLs).

Methods: Cochrane Library, PubMed and Web of Science databases were systematically searched and checked for studies using CEUS in characterization of FLLs. Data necessary to construct 2×2 contingency tables were extracted from included studies. The QUADAS tool was utilized to assess the methodologic quality of the studies. Meta-analysis included data pooling, subgroup analyses, meta-regression and investigation of publication bias was comprehensively performed.

Results: Fifty-seven studies were included in this meta-analysis and the overall diagnostic accuracy in characterization of FLLs was as follows: pooled sensitivity, 0.92 (95%CI: 0.91-0.93); pooled specificity, 0.87 (95%CI: 0.86-0.88); diagnostic odds ratio, 104.20 (95%CI: 70.42-154.16). Subgroup analysis indicated higher diagnostic accuracy of the second-generation contrast agents (CAs) than the first-generation CA (Levovist; DOR: 118.27 vs. 62.78). Furthermore, Sonazoid demonstrated the highest diagnostic accuracy among three major CAs (SonoVue, Levovist and Sonazoid; DOR: 118.82 vs. 62.78 vs. 227.39). No potential publication bias was observed of the included studies.

Conclusion: CEUS is an accurate tool to stratify the risk of malignancy in FLLs. The second-generation CAs, especially Sonazoid may greatly improve diagnostic performance.

Key points: • CEUS shows excellent diagnostic accuracy in differentiating malignant from benign FLLs. • The second-generation CAs have higher diagnostic accuracy than first-generation CAs. • Sonazoid demonstrates the highest diagnostic accuracy among three major CAs.

Keywords: Contrast media; Diagnosis; Liver neoplasms; Meta-analysis; Ultrasonography.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Ultraschall Med. 2008 Oct;29(5):499-505 - PubMed
    1. J Ultrasound Med. 2004 Dec;23 (12 ):1557-68 - PubMed
    1. J Gastroenterol Hepatol. 2008 Oct;23 (10 ):1511-9 - PubMed
    1. Med Phys. 2015 Jul;42(7):3948-59 - PubMed
    1. Radiology. 2004 Aug;232(2):420-30 - PubMed

LinkOut - more resources