Electronic remote blood issue combined with a computer-controlled, automated refrigerator for major surgery in operating theatres at a distance from the transfusion service
- PMID: 29193169
- DOI: 10.1111/trf.14418
Electronic remote blood issue combined with a computer-controlled, automated refrigerator for major surgery in operating theatres at a distance from the transfusion service
Abstract
Background: The difficulty of supplying red blood cells within an adequate time to patients undergoing surgery is a known problem for transfusion services, particularly if the operating theater is located at some distance from the blood bank. The consequences frequently are that more blood is ordered than required; several units are allocated and issued; and unused units must be returned to the blood bank. Some sparse reports have demonstrated that remote blood issue systems can improve the efficiency of issuing blood.
Study design and methods: This study describes a computer-controlled, self-service, remote blood-release system, combined with an automated refrigerator, installed in a hospital at which major surgery was performed, located 5 kilometers away from the transfusion service. With this system, red blood cell units were electronically allocated to patients immediately before release, when the units actually were needed. Two 2-year periods, before and after implementation of the system, were compared.
Results: After implementation of the system, the ratio of red blood cell units returned to the transfusion service was reduced from 48.9% to 1.6% of the issued units (8852 of 18,090 vs. 182 of 11,152 units; p < 0.0001), and the issue-to-transfusion ratio was reduced from 1.96 to 1.02. An increase in the number of transfused red blood cell units was observed, probably mainly due to changes in the number and complexity of surgical procedures. No transfusion errors occurred in the two periods.
Conclusion: The current results demonstrate that the remote blood-release system is safe and useful for improving the efficiency of blood issue for patients in remote operating theatres.
© 2017 AABB.
Similar articles
-
Excessive quantities of red blood cells are issued to the operating room.Transfus Med. 2015 Dec;25(6):374-9. doi: 10.1111/tme.12263. Epub 2015 Dec 10. Transfus Med. 2015. PMID: 26663506
-
Electronic remote blood issue: a combination of remote blood issue with a system for end-to-end electronic control of transfusion to provide a "total solution" for a safe and timely hospital blood transfusion service.Transfusion. 2008 Mar;48(3):415-24. doi: 10.1111/j.1537-2995.2007.01545.x. Epub 2007 Dec 7. Transfusion. 2008. PMID: 18067511
-
Introduction of a closed-system cell processor for red blood cell washing: postimplementation monitoring of safety and efficacy.Transfusion. 2016 Jan;56(1):49-57. doi: 10.1111/trf.13341. Epub 2015 Oct 7. Transfusion. 2016. PMID: 26444143
-
[Clinical impact of length of storage before red blood cell transfusion].Transfus Clin Biol. 2011 Apr;18(2):97-105. doi: 10.1016/j.tracli.2011.02.020. Epub 2011 Apr 3. Transfus Clin Biol. 2011. PMID: 21459646 Review. French.
-
Hitchhiker's guide to the red cell storage galaxy: Omics technologies and the quality issue.Transfus Apher Sci. 2017 Apr;56(2):248-253. doi: 10.1016/j.transci.2017.03.006. Epub 2017 Mar 9. Transfus Apher Sci. 2017. PMID: 28343934 Review.
Cited by
-
Reducing perioperative red blood cell unit issue orders, returns, and waste using failure modes and effects analysis.Transfusion. 2023 Apr;63(4):755-762. doi: 10.1111/trf.17275. Epub 2023 Feb 8. Transfusion. 2023. PMID: 36752098 Free PMC article.
-
Electronic transfusion consent and blood delivering pattern improve the management of blood bank in China.BMC Health Serv Res. 2022 Apr 26;22(1):561. doi: 10.1186/s12913-022-07825-6. BMC Health Serv Res. 2022. PMID: 35473708 Free PMC article.
-
Unlocking the potential of electronic blood transfusion systems: Implementation insights from NHS hospitals in England.Br J Haematol. 2025 Jul;207(1):235-243. doi: 10.1111/bjh.20198. Epub 2025 Jun 10. Br J Haematol. 2025. PMID: 40494819 Free PMC article.