. 2018 Jan;50(1):70-77.
doi: 10.1002/lsm.22758. Epub 2017 Nov 29.

The fractional laser-induced coagulation zone characterized over time by laser scanning confocal microscopy-A proof of concept study

Affiliations

The fractional laser-induced coagulation zone characterized over time by laser scanning confocal microscopy-A proof of concept study

Christina A Banzhaf et al. Lasers Surg Med. 2018 Jan.

Abstract

Background: Ablative fractional laser (AFXL) is an acknowledged technique to increase uptake of topical agents in skin. Micro thermal ablation zones (MAZs) consist of ablated vertical channels surrounded by a coagulation zone (CZ). Laser scanning confocal microscopy (LSCM) images individual MAZs at 733 nm (reflectance confocal microscopy (RCM)). Further, LSCM can image sodium fluorescein (NaF) fluorescence with 488 nm excitation (fluorescence confocal microcopy (FCM)), a small hydrophilic test molecule (370 MW, log P -1.52), which may simulate uptake, bio-distribution and kinetics of small hydrophilic drugs.

Objectives: To explore LSCM for combined investigations of CZ thickness and uptake, bio-distribution and kinetics of NaF in AFXL-exposed skin.

Study designs/methods and materials: Excised human abdominal skin samples were exposed to AFXL (15 mJ/microbeam, 2% density) and NaF gel (1000 μg/ml, 10 μl/cm2) in six repetitions, including untreated control samples. CZ thickness and spatiotemporal fluorescence intensities (FI) were quantified up to four hours after NaF application by RCM and FCM. Test sites were scanned to a depth of 200 μm, quantifying thickness of skin compartments (stratum corneum, epidermis, upper dermis), individual CZ thicknesses and FI in CZ and surrounding skin.

Results: RCM images established skin morphology to a depth of 200 μm. The CZ thickness measurements were feasible to a depth of 50 μm, and remained unchanged over time at 50 μm (P > 0.5). FI were detected to a depth of 160 μm and remained constant in CZ up to four hours after NaF application (15 minutes: 79 AU (73-92 AU), 60 minutes: 72 AU (58-82 AU), four hours: 78 AU (71-90 AU), P > 0.1). In surrounding skin, FI increased significantly over time, but remained lower than FI in CZ (15 minutes: 21 AU (17-22 AU), 60 minutes: 21 AU (19-26 AU), four hours: 42 (31- 48 AU), P = 0.03). AFXL-processed skin generated higher FI compared to non-laser processed skin in epidermis and upper dermis at 60 minutes and four hours (P = 0.03).

Conclusions: By LSCM, assessment of the AFXL-induced CZ thickness was feasible to a depth of 50 μm, and assessment of FI from a small hydrophilic test molecule, NaF in CZ and surrounding skin feasible to a depth of 160 μm. Lasers Surg. Med. 50:70-77, 2018. © 2017 Wiley Periodicals, Inc.

Keywords: Fluorescence confocal microscopy; fluorescence intensity; imaging; micro thermal ablation zone; reflectance confocal microscopy; sodium fluorescein; topical drug delivery.