SPR imaging biosensor for the quantitation of fibronectin concentration in blood samples
- PMID: 29202303
- DOI: 10.1016/j.jpba.2017.11.070
SPR imaging biosensor for the quantitation of fibronectin concentration in blood samples
Abstract
The purpose of this study was presentation of a new biosensor capable of determination of fibronectin. This biosensor was based on the specific interaction of anti-fibronectin antibody produced in rabbit with fibronectin. The surface plasmon resonance imaging (SPRI) technique was used as a detecting method. Optimization and characterization properties of the biosensor were studied. The determination of fibronectin concentration in natural samples was done. The results were compared with a reference method (Enzyme-Linked Immunosorbent Assay-ELISA). The analytically useful dynamic response range of biosensor is between 5 and 400ngmL-1. The detection limit is 1.5ngmL-1 and limit quantification is 5ngmL-1. The proposed SPRI biosensor showed good selectivity for potential interferences. It was applied to determine fibronectin concentrations in plasma of healthy donors and of patients after thermal injury. Good correlations between results obtained using the SPRI biosensor and ELISA test (correlation coefficients for healthy donors 0.996, for patients 0.984) were obtained. The average fibronectin concentration of healthy donors was 140.5±24.6μgmL -1 and the average fibronectin concentration of patients was 601.5±72.1μgmL -1, which was in agreement with results obtained by other investigators. The obtained results indicate that the developed biosensor may be a candidate for monitoring fibronectin concentration in blood samples.
Keywords: Biosensor; Fibronectin; Surface plasmon resonance imaging.
Copyright © 2017 Elsevier B.V. All rights reserved.
Similar articles
-
SPR imaging biosensor for determination of laminin-5 as a potential cancer marker in biological material.Anal Bioanal Chem. 2016 Jul;408(19):5269-76. doi: 10.1007/s00216-016-9621-x. Epub 2016 May 21. Anal Bioanal Chem. 2016. PMID: 27209594 Free PMC article.
-
Sensitive and selective analysis of a wide concentration range of IGFBP7 using a surface plasmon resonance biosensor.Colloids Surf B Biointerfaces. 2014 Nov 1;123:887-91. doi: 10.1016/j.colsurfb.2014.10.037. Epub 2014 Oct 28. Colloids Surf B Biointerfaces. 2014. PMID: 25466460
-
Matrix metalloproteinase-2 and its correlation with basal membrane components laminin-5 and collagen type IV in paediatric burn patients measured with Surface Plasmon Resonance Imaging (SPRI) biosensors.Burns. 2018 Jun;44(4):931-940. doi: 10.1016/j.burns.2017.12.001. Epub 2018 Feb 1. Burns. 2018. PMID: 29395405
-
Surface plasmon resonance: a versatile technique for biosensor applications.Sensors (Basel). 2015 May 5;15(5):10481-510. doi: 10.3390/s150510481. Sensors (Basel). 2015. PMID: 25951336 Free PMC article. Review.
-
Rapid and label-free bacteria detection by surface plasmon resonance (SPR) biosensors.Biotechnol J. 2009 Jul;4(7):1003-11. doi: 10.1002/biot.200800316. Biotechnol J. 2009. PMID: 19288516 Review.
Cited by
-
Recent Progress in Surface Plasmon Resonance Biosensors (2016 to Mid-2018).Biosensors (Basel). 2018 Dec 16;8(4):132. doi: 10.3390/bios8040132. Biosensors (Basel). 2018. PMID: 30558384 Free PMC article. Review.
-
Levels of Selected Matrix Metalloproteinases-MMP-1, MMP-2 and Fibronectin in the Saliva of Patients Planned for Endodontic Treatment or Surgical Extraction.J Clin Med. 2020 Dec 7;9(12):3971. doi: 10.3390/jcm9123971. J Clin Med. 2020. PMID: 33297580 Free PMC article.
-
The Levels of Leptin, Cystatin C, Neuropilin-1 and Tau Protein in Relation to Dietary Habits in Patients with Alzheimer's Disease.J Clin Med. 2023 Oct 30;12(21):6855. doi: 10.3390/jcm12216855. J Clin Med. 2023. PMID: 37959320 Free PMC article.
-
Recent Progress in Optical Sensors for Biomedical Diagnostics.Micromachines (Basel). 2020 Mar 30;11(4):356. doi: 10.3390/mi11040356. Micromachines (Basel). 2020. PMID: 32235546 Free PMC article. Review.
-
Advances in Molecularly Imprinted Polymers Based Affinity Sensors (Review).Polymers (Basel). 2021 Mar 22;13(6):974. doi: 10.3390/polym13060974. Polymers (Basel). 2021. PMID: 33810074 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical