Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2018 Mar;155(3):915-923.
doi: 10.1016/j.jtcvs.2017.10.071. Epub 2017 Nov 2.

Balloon-expandable transaortic transcatheter aortic valve implantation with or without predilation

Affiliations
Free article
Comparative Study

Balloon-expandable transaortic transcatheter aortic valve implantation with or without predilation

Nikolaos Bonaros et al. J Thorac Cardiovasc Surg. 2018 Mar.
Free article

Abstract

Objective: It has been reported that balloon aortic valvuloplasty immediately before transfemoral or transapical transcatheter aortic valve implantation has mostly little to no clinical value. We aimed to provide data on the need for balloon aortic valvuloplasty in patients undergoing transaortic transcatheter aortic valve implantation.

Methods: Patients undergoing transaortic transcatheter aortic valve implantation with the Edwards SAPIEN XT (Nyon, Switzerland) or 3 transcatheter heart valve were prospectively included at 18 sites across Europe. In the present analysis, we compare the periprocedural and 30-day outcomes of patients undergoing conventional (+ balloon aortic valvuloplasty) versus direct (- balloon aortic valvuloplasty) transaortic transcatheter aortic valve implantation.

Results: Of the 300 patients enrolled, 222 underwent conventional and 78 underwent direct transaortic transcatheter aortic valve implantation. Peak and mean transvalvular gradients were improved in both groups with no significant difference between groups. Procedural duration, contrast agent volume, and requirement for postdilation were also comparable. A trend toward fewer periprocedural complications was evident in the direct group (3.9% vs 11.3%; P = .053), with significantly lower rates of permanent pacemaker implantation (0% vs 5.0%; P = .034). Balloon aortic valvuloplasty omission had no significant effect on any of the 30-day safety and efficacy outcomes, including Valve Academic Research Consortium-2 composite end points (early safety events: 22.7% vs 17.4%, odds ratio, 1.17, 95% confidence interval, 0.53-2.62; clinical efficacy events: 20.5% vs 18.7%, odds ratio, 1.14, 95% confidence interval, 0.51-2.55).

Conclusions: For many patients, balloon aortic valvuloplasty predilation seems to have little clinical value in transaortic transcatheter aortic valve implantation using a balloon expandable transcatheter valve and may result in a higher rate of periprocedural complications, particularly in terms of permanent pacemaker implantation.

Keywords: aortic stenosis; balloon aortic valvuloplasty; predilation; transaortic; transcatheter aortic valve implantation.

PubMed Disclaimer

Comment in

MeSH terms