Fetal Electrocardiogram Extraction and Analysis Using Adaptive Noise Cancellation and Wavelet Transformation Techniques
- PMID: 29222728
- DOI: 10.1007/s10916-017-0868-3
Fetal Electrocardiogram Extraction and Analysis Using Adaptive Noise Cancellation and Wavelet Transformation Techniques
Abstract
Birth defect-related demise is mainly due to congenital heart defects. In the earlier stage of pregnancy, fetus problem can be identified by finding information about the fetus to avoid stillbirths. The gold standard used to monitor the health status of the fetus is by Cardiotachography(CTG), cannot be used for long durations and continuous monitoring. There is a need for continuous and long duration monitoring of fetal ECG signals to study the progressive health status of the fetus using portable devices. The non-invasive method of electrocardiogram recording is one of the best method used to diagnose fetal cardiac problem rather than the invasive methods.The monitoring of the fECG requires development of a miniaturized hardware and a efficient signal processing algorithms to extract the fECG embedded in the mother ECG. The paper discusses a prototype hardware developed to monitor and record the raw mother ECG signal containing the fECG and a signal processing algorithm to extract the fetal Electro Cardiogram signal. We have proposed two methods of signal processing, first is based on the Least Mean Square (LMS) Adaptive Noise Cancellation technique and the other method is based on the Wavelet Transformation technique. A prototype hardware was designed and developed to acquire the raw ECG signal containing the mother and fetal ECG and the signal processing techniques were used to eliminate the noises and extract the fetal ECG and the fetal Heart Rate Variability was studied. Both the methods were evaluated with the signal acquired from a fetal ECG simulator, from the Physionet database and that acquired from the subject. Both the methods are evaluated by finding heart rate and its variability, amplitude spectrum and mean value of extracted fetal ECG. Also the accuracy, sensitivity and positive predictive value are also determined for fetal QRS detection technique. In this paper adaptive filtering technique uses Sign-sign LMS algorithm and wavelet techniques with Daubechies wavelet, employed along with de noising techniques for the extraction of fetal Electrocardiogram.Both the methods are having good sensitivity and accuracy. In adaptive method the sensitivity is 96.83, accuracy 89.87, wavelet sensitivity is 95.97 and accuracy is 88.5. Additionally, time domain parameters from the plot of heart rate variability of mother and fetus are analyzed.
Keywords: Adaptive Noise Cancellation; Cardiotachography; Fetal ECG; Wavelet Transform and Heart Rate Variability.
Similar articles
-
Research of fetal ECG extraction using wavelet analysis and adaptive filtering.Comput Biol Med. 2013 Oct;43(10):1622-7. doi: 10.1016/j.compbiomed.2013.07.028. Epub 2013 Aug 2. Comput Biol Med. 2013. PMID: 24034754
-
Detection of fetal arrhythmia by adaptive single channel electrocardiogram extraction.Phys Eng Sci Med. 2021 Sep;44(3):683-692. doi: 10.1007/s13246-021-01016-z. Epub 2021 Jun 25. Phys Eng Sci Med. 2021. PMID: 34170500
-
Noninvasive fetal electrocardiography: an overview of the signal electrophysiological meaning, recording procedures, and processing techniques.Ann Noninvasive Electrocardiol. 2015 Jul;20(4):303-13. doi: 10.1111/anec.12259. Epub 2015 Feb 2. Ann Noninvasive Electrocardiol. 2015. PMID: 25640061 Free PMC article. Review.
-
Robust fetal QRS detection from noninvasive abdominal electrocardiogram based on channel selection and simultaneous multichannel processing.Australas Phys Eng Sci Med. 2015 Dec;38(4):581-92. doi: 10.1007/s13246-015-0381-2. Australas Phys Eng Sci Med. 2015. PMID: 26462679
-
Non-Adaptive Methods for Fetal ECG Signal Processing: A Review and Appraisal.Sensors (Basel). 2018 Oct 27;18(11):3648. doi: 10.3390/s18113648. Sensors (Basel). 2018. PMID: 30373259 Free PMC article. Review.
Cited by
-
Efficient implementation of LMS adaptive filter-based FECG extraction on an FPGA.Healthc Technol Lett. 2020 Nov 13;7(5):125-131. doi: 10.1049/htl.2020.0016. eCollection 2020 Oct. Healthc Technol Lett. 2020. PMID: 33282322 Free PMC article.
-
A Null Space-Based Blind Source Separation for Fetal Electrocardiogram Signals.Sensors (Basel). 2020 Jun 22;20(12):3536. doi: 10.3390/s20123536. Sensors (Basel). 2020. PMID: 32580397 Free PMC article.
-
Fetal Heart Rate Extraction Based on Wavelet Transform to Prevent Fetal Distress In Utero.J Healthc Eng. 2021 Sep 29;2021:7608785. doi: 10.1155/2021/7608785. eCollection 2021. J Healthc Eng. 2021. Retraction in: J Healthc Eng. 2023 Oct 11;2023:9817463. doi: 10.1155/2023/9817463. PMID: 34630995 Free PMC article. Retracted.
-
[A fetal electrocardiogram signal extraction method based on long short term memory network optimized by genetic algorithm].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2021 Apr 25;38(2):257-267. doi: 10.7507/1001-5515.202004063. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2021. PMID: 33913285 Free PMC article. Chinese.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical