Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Dec:75:133-139.
doi: 10.1016/j.oraloncology.2017.11.011. Epub 2017 Nov 11.

Utilization of a pre-bent plate-positioning surgical guide system in precise mandibular reconstruction with a free fibula flap

Affiliations

Utilization of a pre-bent plate-positioning surgical guide system in precise mandibular reconstruction with a free fibula flap

Tingwei Bao et al. Oral Oncol. 2017 Dec.

Abstract

Objectives: We evaluated the effects of three-dimensional virtual planning and the use of a plate-embedded surgical guide in mandibular reconstruction with microvascular fibula flaps.

Materials and methods: We retrospectively reviewed 35 patients who underwent primary mandibular reconstruction with a free fibula flap. They were divided into three groups according to the therapy they received. In group A, 12 patients underwent reconstruction using the modified surgical guide system, including virtual surgeries, pre-bent titanium plates, screw-predesignated cutting guides for mandibular and fibular osteotomies, and plate-embedded shaping guides. In group B, 14 patients underwent reconstruction using the common surgical guide system, including virtual surgeries, cutting guides and pre-bent plates. In group C, 9 patients underwent reconstruction based on the surgeon's experience. All cases were reviewed for the total operative time, ischemia time of the fibula flaps, accuracy of surgery, and postoperative complications.

Results: All of the fibula flaps survived. In group A, the ischemia time was shorter than that of groups B and C (P < .05). The average gonion and condyle shift was lower in group A than in groups B and C (P < .01).

Conclusions: Application of the screw-predesignated and plate-embedded surgical guide system can reduce the ischemia time and operation time in mandibular reconstruction with a fibula flap, and can increase reconstruction accuracy. This method is a precise and highly reliable technique for improving the clinical outcome of mandibular reconstruction.

Keywords: Fibula flap; Mandibular reconstruction; Navigation; Plate positioning; Pre-bent plate; Surgical guide; Virtual planning surgery.

PubMed Disclaimer

Publication types

LinkOut - more resources