. 2017 Dec;93(6):316-321.
doi: 10.4174/astr.2017.93.6.316. Epub 2017 Dec 1.

Efficacy and safety of a novel partially absorbable mesh in totally extraperitoneal hernia repair

Affiliations

Efficacy and safety of a novel partially absorbable mesh in totally extraperitoneal hernia repair

Hsien Wen Yang et al. Ann Surg Treat Res. 2017 Dec.

Abstract

Purpose: Partially absorbable mesh has been introduced and used for inguinal hernia repair for the purpose of minimizing pain and improving abdominal wall compliance. In this study, we evaluate the efficacy and safety of ProFlex mesh, a partially absorbed mesh with new structural architecture.

Methods: We retrospectively reviewed 64 cases of totally extraperitoneal herniorrhapy (TEP) from January 2013 to December 2014 for their clinical features, including operation time, pain, postoperative complications, and recurrence.

Results: There were no significant differences in operation time, hospital stay, postoperative pain, or complications between the 28 patients who received the ProFlex mesh and the 36 who received nonabsorbable lightweight mesh, although one patient who received the nonabsorbable had a recurrence during follow-up. There were differences in operation time, complications, and hospital stay according to the surgeon's previous operation volume.

Conclusion: This study showed that there were significant differences in the fixation strength of different polypropylene meshes in combination with various fibrin glues. ProFlex, a partially absorbable mesh with new architecture, was feasible and safe in TEP.

Keywords: Hernia; Surgical mesh.

PubMed Disclaimer

Conflict of interest statement

CONFLICTS OF INTEREST: No potential conflict of interest relevant to this article was reported.

Figures

Fig. 1
Fig. 1. Composition of and changes in ProFlex (Samyang Bio farm, Seoul, Korea) partially absorbable mesh. PP, polypropylene, PGA-PCL, poly (glycolide-co-caprolactone).

Similar articles

Cited by

References

    1. Bay-Nielsen M, Kehlet H, Strand L, Malmstrom J, Andersen FH, Wara P, et al. Quality assessment of 26,304 herniorrhaphies in Denmark: a prospective nationwide study. Lancet. 2001;358:1124–1128. - PubMed
    1. EU Hernia Trialists Collaboration. Repair of groin hernia with synthetic mesh: meta-analysis of randomized controlled trials. Ann Surg. 2002;235:322–332. - PMC - PubMed
    1. van Veen RN, Wijsmuller AR, Vrijland WW, Hop WC, Lange JF, Jeekel J. Long-term follow-up of a randomized clinical trial of non-mesh versus mesh repair of primary inguinal hernia. Br J Surg. 2007;94:506–510. - PubMed
    1. Klinge U, Klosterhalfen B, Müller M, Schumpelick V. Foreign body reaction to meshes used for the repair of abdominal wall hernias. Eur J Surg. 1999;165:665–673. - PubMed
    1. Cunningham J, Temple WJ, Mitchell P, Nixon JA, Preshaw RM, Hagen NA. Cooperative hernia study. Pain in the postrepair patient. Ann Surg. 1996;224:598–602. - PMC - PubMed