Evaluation of Physicochemical Properties of a New Root Canal Sealer

Affiliations

Evaluation of Physicochemical Properties of a New Root Canal Sealer

Gislene Cristina Vertuan et al. J Endod. 2018 Mar.

Abstract

Introduction: The aim of this study was to evaluate some of the physicochemical properties of a new root canal sealer.

Methods: The sealers tested were Sealer Plus compared with AH Plus. For the radiopacity, flow, solubility, and fabrication of test specimens relative to setting times, the American National Standards Institute/American Dental Association No. 57 (2000) and International Organization for Standardization 6876 (2012) specifications were followed. To measure the initial and final setting times, the ASTM C266/2008 standard was used. pH was evaluated in the time intervals of 3, 24, 72, and 168 hours. Statistical tests were applied to the results obtained at a level of significance of 5%.

Results: The results demonstrated that the Sealer Plus sealer showed a lower radiopacity value than AH Plus sealer (P < .05); however, this was higher than the minimum value recommended by the specifications (ie, 3 mm Al). Relative to flow, the value for Sealer Plus was 19.19 mm and for AH Plus, 19.81 mm (P > .05). Sealer Plus presented initial and final setting times of 138 minutes and 210 minutes, respectively, whereas the values for AH Plus were 437 minutes and 849 minutes, respectively (P < .05). Relative to solubility, Sealer Plus presented 0.21% and AH Plus, 0.27% (P > .05). None of the sealers showed a significant increase in pH (P > .05).

Conclusions: Sealer Plus sealer presented physicochemical properties in accordance with American National Standards Institute/American Dental Association (2000) No. 57 and International Organization for Standardization 6876 (2012) specifications.

Keywords: Endodontic sealers; materials testing; physical and chemical properties; resin epoxy; root canal obturation.