Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Feb 6;90(3):1635-1642.
doi: 10.1021/acs.analchem.7b02961. Epub 2018 Jan 16.

Frequency-Based Analysis of Gramicidin A Nanopores Enabling Detection of Small Molecules with Picomolar Sensitivity

Affiliations
Free article

Frequency-Based Analysis of Gramicidin A Nanopores Enabling Detection of Small Molecules with Picomolar Sensitivity

Young Hun Kim et al. Anal Chem. .
Free article

Abstract

Methods to detect low concentrations of small molecules are useful for a wide range of analytical problems including the development of clinical assays, the study of complex biological systems, and the detection of biological warfare agents. This paper describes a semisynthetic ion channel platform capable of detecting small molecule analytes with picomolar sensitivity. Our methodology exploits the transient nature of ion channels formed from gramicidin A (gA) nanopores and the frequency of observed single channel events as a function of concentration of free gA molecules that reversibly dimerize in a bilayer membrane. We initially use a protein (here, a monoclonal antibody) to sequester the ion channel activity of a C-terminally modified gA derivative. When a small molecule analyte is introduced to the electrical recording medium, it competitively binds to the protein and liberates the gA derivative, restoring its single ion channel activity. We found that monitoring the frequency of gA channel events makes it possible to detect picomolar concentrations of small molecule in solution. In part, due to the digital on/off nature of frequency-based analysis, this approach is 103 times more sensitive than measuring macroscopic membrane ion flux through gA channels as a basis for detection. This novel methodology, therefore, significantly improves the limit of detection of nanopore-based sensors for small molecule analytes, which has the potential for incorporation into miniaturized and low cost devices that could complement current established assays.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms