Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Jan;51(1):5-12.
doi: 10.1007/s10840-017-0305-z. Epub 2017 Dec 23.

Impact of quadripolar LV leads on heart failure hospitalization rates among patients implanted with CRT-D: data from the Israeli ICD Registry

Affiliations

Impact of quadripolar LV leads on heart failure hospitalization rates among patients implanted with CRT-D: data from the Israeli ICD Registry

Eran Leshem et al. J Interv Card Electrophysiol. 2018 Jan.

Abstract

Background: Cardiac resynchronization therapy (CRT) is an effective treatment for heart failure (HF); however, a third of patients are non-responders. The development of quadripolar left ventricular (LV) lead was shown, mainly in single manufactures' registry, to improve LV remodeling and overall mortality. However, limited reports exist on the impact of quadripolar LV leads on HF hospitalization rates in real-life cohorts. We evaluated the clinical outcomes associated with quadripolar LV leads in a large nation-wide registry including all patients implanted with a cardiac resynchronization therapy with defibrillator (CRT-D).

Methods: Between July 2010 and October 2016, 2913 consecutive patients were implanted with a CRT-D and all were prospectively enrolled in the Israeli ICD Registry. Quadripolar LV leads were implanted in 973 (33.4%) patients during this period, and their clinical outcomes were compared to CRT-D recipients implanted with a bipolar LV lead. Primary endpoint was HF hospitalization rate.

Results: Quadripolar leads were implanted more in patients with non-ischemic cardiomyopathy and for primary prevention indication and less in post-infarction patients and for secondary prevention of sudden death. Longer QRS duration was observed with quadripolar leads (147 ± 23 vs 143 ± 25; p < 0.001). Outcome event rate for 100 patient years revealed no difference in HF hospitalization rates between bipolar and quadripolar LV leads. Quadripolar lead implant led to lower cardiac mortality, with no influence on overall mortality. Multivariate analysis revealed no significant differences in study endpoints between bipolar and quadripolar LV leads.

Conclusion: In a large real-life registry, implantation of quadripolar LV leads in patients with CRT-D did not influence HF hospitalization rates.

Keywords: CRT-D; Heart failure; Hospitalization; Mortality; Quadripolar LV leads.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Europace. 2013 Aug;15(8):1070-118 - PubMed
    1. J Cardiovasc Electrophysiol. 2016 Jul;27(7):840-5 - PubMed
    1. Europace. 2017 Sep 1;19(9):1485-1492 - PubMed
    1. Int J Cardiol. 2016 Dec 15;225:345-352 - PubMed
    1. Europace. 2014 Aug;16(8):1175-80 - PubMed

MeSH terms

LinkOut - more resources