Non-invasive Assessment of Significant Dehydration in Infants Using the Inferior Vena Cava to Aortic Ratio: Is it Useful?
- PMID: 29287013
- DOI: 10.1097/MPG.0000000000001865
Non-invasive Assessment of Significant Dehydration in Infants Using the Inferior Vena Cava to Aortic Ratio: Is it Useful?
Abstract
Objectives: The aim of the study was to assess the accuracy of the inferior vena cava to aorta (IVC/Ao) diameter ratio for predicting significant dehydration in infants relative to their percentage weight change and the clinical diagnosis by a physician.
Methods: A prospective observational study was performed on 200 infants presented with acute diarrhea and clinical evidence of significant dehydration whose treatment required intravenous (IV) fluids as determined by the attending physician at the pediatric emergency department of Tanta University Hospital. Weight was recorded at admission before IV fluid treatment and at hospital discharge. The percentage of dehydration was determined using the following formula: (discharge weight - admission weight)/discharge weight × 100%. Patients with a percentage weight change of <5% were considered to be nonsignificantly dehydrated, whereas patients with a percentage weight change >5% were considered significantly dehydrated. The IVC/Ao diameter ratio was measured for all patients before IV fluid rehydration and again at discharge.
Results: Only 134 out of 200 dehydrated infants were found to be significantly dehydrated using the gold standard, percentage weight change. Receiver operating characteristics (ROC) curve analysis of the prehydration IVC/Ao ratio showed a sensitivity of 82%, a specificity of 91%, and an accuracy of 87% for predicting significant dehydration in infants at a cut-off point of less than 0.75. In contrast, physician clinical diagnosis showed a sensitivity of 70%, a specificity of 63%, and an accuracy of 73%.
Conclusions: The IVC/Ao diameter ratio can be used as a reliable predictor for diagnosing significant dehydration in infants.
Similar articles
-
Accuracy of Inferior Vena Cava Ultrasound for Predicting Dehydration in Children with Acute Diarrhea in Resource-Limited Settings.PLoS One. 2016 Jan 14;11(1):e0146859. doi: 10.1371/journal.pone.0146859. eCollection 2016. PLoS One. 2016. PMID: 26766306 Free PMC article.
-
Use of ultrasound measurement of the inferior vena cava diameter as an objective tool in the assessment of children with clinical dehydration.Acad Emerg Med. 2007 Oct;14(10):841-5. doi: 10.1197/j.aem.2007.06.040. Acad Emerg Med. 2007. PMID: 17898246 Clinical Trial.
-
Use of bedside ultrasound to assess degree of dehydration in children with gastroenteritis.Acad Emerg Med. 2010 Oct;17(10):1042-7. doi: 10.1111/j.1553-2712.2010.00873.x. Acad Emerg Med. 2010. PMID: 21040104 Free PMC article.
-
Use of POCUS for the assessment of dehydration in pediatric patients-a narrative review.Eur J Pediatr. 2024 Mar;183(3):1091-1105. doi: 10.1007/s00431-023-05394-2. Epub 2023 Dec 22. Eur J Pediatr. 2024. PMID: 38133810 Review.
-
Point-of-care ultrasound to assess degree of dehydration in children: a systematic review with meta-analysis.Arch Dis Child. 2024 Mar 19;109(4):275-281. doi: 10.1136/archdischild-2023-325403. Arch Dis Child. 2024. PMID: 37315988
Cited by
-
Point-of-care ultrasound for children.J Med Ultrason (2001). 2022 Oct;49(4):639-654. doi: 10.1007/s10396-021-01169-0. Epub 2022 Jan 21. J Med Ultrason (2001). 2022. PMID: 35059920 Review.
-
Feline caudal vena cava to aorta ratio reference interval.J Feline Med Surg. 2024 Dec;26(12):1098612X241303309. doi: 10.1177/1098612X241303309. J Feline Med Surg. 2024. PMID: 39703188 Free PMC article.
-
Inferior vena cava to aorta ratio in dehydrated pediatric patients: a systematic review and meta-analysis.Clin Exp Pediatr. 2023 Nov;66(11):477-484. doi: 10.3345/cep.2022.01445. Epub 2023 Jun 14. Clin Exp Pediatr. 2023. PMID: 37321576 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical