Effects of pressure-demand respirator wear on physiological and perceptual variables during progressive exercise to maximal levels
- PMID: 2929430
- DOI: 10.1080/15298668991374345
Effects of pressure-demand respirator wear on physiological and perceptual variables during progressive exercise to maximal levels
Abstract
Current regulations governing the certification of respiratory protective devices are based on data published in the early 1950s. The limited data base of this early work and documented increases in the average height of the population underscore the need for additional information concerning the parameters of certification. In the present study, a protocol using an inclined treadmill (0.5% grade every 12 sec) was used to test a heterogeneous population (n = 38). Through submaximal up to and including maximal exercise levels with and without respirator wear, maximal oxygen uptake (VO2max) was significantly greater (p less than 0.01) with the respirator (44.11 +/- 1.3 mL/kg.min) than without the respirator (42.18 +/- 1.4 mL/kg.min) while maximal ventilation volumes (VEmax) were not significantly different (with = 118.7 +/- 4 L/min; without 119.6 +/- 5 L/min). While peak inspired flows (PFI) with the respirator (268 +/- 7 L/min) were less than without the respirator (281 +/- 9 L/min), p greater than 0.05, the lower peak expired flow (PFE) with the respirator (289 +/- 12 L/min) than without the respirator (324 +/- 13 L/min), p less than 0.01, indicated a significant blunting effect of the respiratory flows by the expired resistance during exercise to maximal levels. Peak inspired pressures (PPi) with and without the respirator were not significantly different (p greater than 0.05). The negative values obtained within the facepiece of the respirator (-7.65 +/- 0.8 cmH2O), however, indicate that the positive pressure within the facepiece was lost, and respiratory protection may be compromised. Peak expired pressure with the respirator (13.05 +/- 0.7 cmH2O) was significantly greater than without the respirator (10.7 +/- 0.5 cmH2O) indicating that, despite a lower PFE, greater force was required to overcome the resistances of the respirator on expiration. The dyspnea index, an index of physiological effort; suggests that the subjects were working at a higher percentage of their respiratory reserve with the respirator (p less than 0.05) than without. Perceptually, subjects also felt that breathing with the respirator was more difficult (p less than 0.05). The maximum heart rate and the ratings of perceived exertion were not significantly different between the two tests at maximal exercise levels. Maximum oxygen uptake was considered reached when subjects attained a respiratory exchange ratio of at least 1.15, when a heart rate response at or greater than age-predicted maximum was achieved, when ratings of perceived exertion indicated exhaustion, and/or when the measure of VO2 had plateaued during the final minute of exercise.(ABSTRACT TRUNCATED AT 400 WORDS)
Similar articles
-
Physiological response to "pressure-demand" respirator wear.Am Ind Hyg Assoc J. 1982 Oct;43(10):773-81. doi: 10.1080/15298668291410567. Am Ind Hyg Assoc J. 1982. PMID: 7148683
-
Alterations in physiological and perceptual variables during exhaustive endurance work while wearing a pressure-demand respirator.Am Ind Hyg Assoc J. 1989 Mar;50(3):139-46. doi: 10.1080/15298668991374426. Am Ind Hyg Assoc J. 1989. PMID: 2718906
-
Effects of industrial respirator wear during exercise in subjects with restrictive lung disease.Am Ind Hyg Assoc J. 1986 Mar;47(3):176-80. doi: 10.1080/15298668691389540. Am Ind Hyg Assoc J. 1986. PMID: 3706144
-
The physiological consequences of wearing industrial respirators: a review.Am Ind Hyg Assoc J. 1979 Jun;40(6):517-34. doi: 10.1080/15298667991429912. Am Ind Hyg Assoc J. 1979. PMID: 384779 Review.
-
Are exhalation valves on N95 filtering facepiece respirators beneficial at low-moderate work rates: an overview.J Occup Environ Hyg. 2012;9(11):617-23. doi: 10.1080/15459624.2012.715066. J Occup Environ Hyg. 2012. PMID: 22978255 Review.
Cited by
-
Design of Web-to-Web Spacing for the Reduced Pressure Drop and Effective Depth Filtration.Polymers (Basel). 2019 Nov 6;11(11):1822. doi: 10.3390/polym11111822. Polymers (Basel). 2019. PMID: 31698747 Free PMC article.
-
Impact of wearing a surgical mask on respiratory function in view of a widespread use during COVID-19 outbreak. A case-series study.Med Lav. 2020 Oct 31;111(5):354-364. doi: 10.23749/mdl.v111i5.9766. Med Lav. 2020. PMID: 33124606 Free PMC article.