Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Jan 5;13(1):e0190652.
doi: 10.1371/journal.pone.0190652. eCollection 2018.

Evaluation of a point-of-care immunoassay test kit 'StrongStep' for cryptococcal antigen detection

Affiliations

Evaluation of a point-of-care immunoassay test kit 'StrongStep' for cryptococcal antigen detection

Edward Mpoza et al. PLoS One. .

Abstract

Background: HIV-associated cryptococcal meningitis is the leading cause of adult meningitis in Sub-Saharan Africa, accounting for 15%-20% of AIDS-attributable mortality. The development of point-of-care assays has greatly improved the screening and diagnosis of cryptococcal disease. We evaluated a point-of-care immunoassay, StrongStep (Liming Bio, Nanjing, Jiangsu, China) lateral flow assay (LFA), for cryptococcal antigen (CrAg) detection in cerebrospinal fluid (CSF) and plasma.

Methods: We retrospectively tested 143 CSF and 77 plasma samples collected from HIV-seropositive individuals with suspected meningitis from 2012-2016 in Uganda. We prospectively tested 90 plasma samples collected from HIV-seropositive individuals with CD4 cell count <100 cells/μL from 2016-2017 as part of a cryptococcal antigenemia screening program. The StrongStep CrAg was tested against a composite reference standard of positive Immy CrAg LFA (Immy, Norman, OK, USA) or CSF culture with statistical comparison by McNemar's test.

Results: StrongStep CrAg had a 98% (54/55) sensitivity and 90% (101/112) specificity in plasma (P = 0.009, versus reference standard). In CSF, the StrongStep CrAg had 100% (101/101) sensitivity and 98% (41/42) specificity (P = 0.99). Adjusting for the cryptococcal antigenemia prevalence of 9% in Uganda and average cryptococcal meningitis prevalence of 37% in Sub-Saharan Africa, the positive predictive value of the StrongStep CrAg was 50% in plasma and 96% in CSF.

Conclusions: We found the StrongStep CrAg LFA to be a sensitive assay, which unfortunately lacked specificity in plasma. In lower prevalence settings, a majority of positive results from blood would be expected to be false positives.

PubMed Disclaimer

Conflict of interest statement

Competing Interests: The authors have declared that no competing interests exist.

References

    1. Rajasingham R, Smith RM, Park BJ, Jarvis JN, Govender NP, Chiller TM, et al. Global burden of disease of HIV-associated cryptococcal meningitis: an updated analysis. The Lancet infectious diseases. 2017;17(8):873–81. Epub 2017/05/10. doi: 10.1016/S1473-3099(17)30243-8 . - DOI - PMC - PubMed
    1. Park BJ, Wannemuehler KA, Marston BJ, Govender N, Pappas PG, Chiller TM. Estimation of the current global burden of cryptococcal meningitis among persons living with HIV/AIDS. Aids. 2009;23(4):525–30. doi: 10.1097/QAD.0b013e328322ffac . - DOI - PubMed
    1. Jarvis JN, Meintjes G, Williams A, Brown Y, Crede T, Harrison TS. Adult meningitis in a setting of high HIV and TB prevalence: findings from 4961 suspected cases. BMC Infect Dis. 2010;10:67. Epub 2010/03/17. doi: 1471-2334-10-67 [pii] doi: 10.1186/1471-2334-10-67 . - DOI - PMC - PubMed
    1. World Health Organization. Rapid advice: Diagnosis, prevention and management of cryptococcal disease in HIV-infected adults, adolescents and children Geneva: World Health Organization; 2011. [updated December; cited 2015 1 Nov]. Available from: http://www.who.int/hiv/pub/cryptococcal_disease2011. - PubMed
    1. Health UMo. Addendum To The National Antiretroviral Treatment Guidelines 2013.

Publication types

Substances