Accuracy of non-invasive blood pressure measurements in obese patients
- PMID: 29323991
- DOI: 10.12968/bjon.2018.27.1.35
Accuracy of non-invasive blood pressure measurements in obese patients
Abstract
This article describes an evidence-based literature review, comparing upper arm and forearm blood pressure measurements using non-invasive devices on obese patients. The focus on blood pressure monitoring was in response to regularly witnessing inappropriately applied blood pressure cuffs on obese patient's upper arms in practice. An inaccurately obtained blood pressure measurement can result in the misdiagnosis and treatment of hypertension. As the prevalence of obesity grows worldwide, healthcare settings need to ensure they have the necessary equipment and trained staff to accurately measure obese patients' blood pressure. The aim of this review was to identify whether a forearm measurement provided a suitable alternative to upper arm measurements. The article discusses the development and execution of a search strategy, as well as the critical appraisal of a selected article. The results of the review demonstrated that forearm blood pressure measurements in obese patients do not replace upper arm blood pressure measurements taken with an appropriate cuff. It is recommended that further research is undertaken in order to identify suitable alternatives for obtaining an accurate non-invasive blood pressure measurement in obese patients.
Keywords: Assessment; Blood pressure; Clinical skills; Evidence-based practice; Hypertension; Non-invasive monitoring; Obesity.
Similar articles
-
Recommendations for blood pressure measurement in large arms in research and clinical practice: position paper of the European society of hypertension working group on blood pressure monitoring and cardiovascular variability.J Hypertens. 2020 Jul;38(7):1244-1250. doi: 10.1097/HJH.0000000000002399. J Hypertens. 2020. PMID: 32141969
-
Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.Blood Press Monit. 2004 Jun;9(3):101-5. doi: 10.1097/01.mbp.0000132425.25263.ac. Blood Press Monit. 2004. PMID: 15199302
-
Validation of a conical cuff on the forearm for estimating radial artery blood pressure.Blood Press Monit. 2014 Feb;19(1):38-45. doi: 10.1097/MBP.0000000000000011. Blood Press Monit. 2014. PMID: 24217368 Clinical Trial.
-
Measurement of blood pressure in the obese.Ann Epidemiol. 1991 May;1(4):321-36. doi: 10.1016/1047-2797(91)90043-c. Ann Epidemiol. 1991. PMID: 1669514 Review.
-
Optimal size of cuff bladder for indirect measurement of arterial pressure in adults.J Hypertens. 1989 Aug;7(8):607-13. doi: 10.1097/00004872-198908000-00002. J Hypertens. 1989. PMID: 2681407 Review.
Cited by
-
Sizing Up General Practice Environments for Big-Bodied Patients: An Environmental Assessment of Three Facilities in Aotearoa, New Zealand.HERD. 2025 Apr;18(2):502-520. doi: 10.1177/19375867241238442. Epub 2024 Mar 21. HERD. 2025. PMID: 38512992 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials