Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Mar;29(3):290-299.
doi: 10.1111/clr.13115. Epub 2018 Jan 12.

Three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses: A prospective multicenter study

Affiliations
Free article

Three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses: A prospective multicenter study

Marc Balmer et al. Clin Oral Implants Res. 2018 Mar.
Free article

Abstract

Aim: The aim of the present investigation was to evaluate clinically and radiographically the outcome of zirconia oral implants after 3 years in function.

Materials and methods: In 60 patients in need of either a single-tooth replacement or a three-unit fixed dental prosthesis (FDP), a total of 71 one-piece zirconia implants were placed and immediately restored with temporary fixed prostheses. After a period of at least 2 months in the mandible and at least 4 months in the maxilla, zirconia-based reconstructions were cemented. The implants were clinically and radiologically examined at implant insertion, prosthetic delivery, at 6 months and then yearly up to 3 years. A linear mixed model was used to analyze statistically the influence of prognostic factors on changes in the marginal bone level.

Results: Seventy-one implants (48 in the mandible, 23 in the maxilla) inserted in 60 patients were restored with 49 crowns and 11 FDP. One patient lost his implant after 5 weeks. Five patients with one implant each could not be evaluated after 3 years. Based on 55 patients with a total of 66 implants, the mean survival rate was 98.5% after 3 years in function. A statistically significant mean marginal bone loss (0.70 mm ± 0.72 mm) has been detected from implant insertion to the 3-year follow-up. The largest marginal bone loss occurred between implantation and prosthetic delivery (0.67 mm ± 0.56 mm). After delivery, no statistically significant bone level change was observed (0.02 mm ± 0.59 mm). None of the investigated prognostic factors had a significant influence on changes in the marginal bone level.

Conclusions: After 3 years in function, the investigated one-piece zirconia implant showed a high survival rate and a low marginal bone loss. The implant system was successful for single-tooth replacement and three-unit FDPs. Further investigations with long-term data are needed to confirm these findings.

Keywords: bone; ceramic; clinical; dental implants; human; osseointegration; zirconia.