Assessment of dimensions and image quality of coronary contrast catheters from cineangiograms
- PMID: 2933154
- DOI: 10.1002/ccd.1810110512
Assessment of dimensions and image quality of coronary contrast catheters from cineangiograms
Abstract
In the quantitative assessment of coronary arterial dimensions from coronary cineangiograms, the contrast catheter is usually used as a scaling device, requiring the definition of the catheter contours by semi- or fully automated contour detection procedures. The image quality of the x-ray radiated catheter is dependent on the catheter material, concentration of the contrast agent in the catheter, and kilovoltage of the x-ray source. The effects of these variables on the image quality and accuracy of the size-measurement of the filmed catheters were studied for four different catheter materials: woven dacron (wd), polyvinylchloride (pv), polyurethane (pu), and nylon. The following parameters were studied: measured size, image contrast, and average brightness gradient along the edges of the displayed catheters. The average differences of the angiographically measured size with the true size for the wd, pv, pu, and nylon catheters were +0.2, -3.2, -3.5, and +9.8%, respectively. The image contrast at various fillings of the catheters was roughly identical for the wd, pv, and pu catheters, and significantly lower for the nylon catheter. Image gradient was highest for the wd catheter, followed by the pv and pu catheters, and lowest for the nylon catheter. From these data it may be concluded that the woven dacron catheter is most suitable for quantitative coronary angiographic studies. The polyvinylchloride and polyurethane catheters perform about equally well but slightly less than the woven dacron catheter. The nylon catheter should not be used for such quantitative studies.
Similar articles
-
Advantages and limitations of two software calipers in quantitative coronary arteriography.Int J Card Imaging. 1991;7(1):15-30. doi: 10.1007/BF01797677. Int J Card Imaging. 1991. PMID: 1753156
-
Angiographic assessment of dimensions of 6F and 7F Mallinckrodt Softouch coronary contrast catheters from digital and cine arteriograms.Int J Card Imaging. 1992;8(2):153-61. doi: 10.1007/BF01137536. Int J Card Imaging. 1992. PMID: 1629641
-
Accuracy and reproducibility of quantitative coronary arteriography using 6 and 8 French catheters with cine angiographic acquisition.Cathet Cardiovasc Diagn. 1991 Jan;22(1):52-5. doi: 10.1002/ccd.1810220113. Cathet Cardiovasc Diagn. 1991. PMID: 1995176
-
Material thrombogenicity in central venous catheterization III. A comparison between soft polyvinylchloride and soft polyurethane elastomer, long, antebrachial catheters.Acta Anaesthesiol Scand. 1984 Apr;28(2):204-8. doi: 10.1111/j.1399-6576.1984.tb02042.x. Acta Anaesthesiol Scand. 1984. PMID: 6730884
-
Limitations of coronary angiography: an underestimated problem?Clin Cardiol. 1991 Jan;14(1):20-4. doi: 10.1002/clc.4960140106. Clin Cardiol. 1991. PMID: 2019026 Review.
Cited by
-
Advantages and limitations of two software calipers in quantitative coronary arteriography.Int J Card Imaging. 1991;7(1):15-30. doi: 10.1007/BF01797677. Int J Card Imaging. 1991. PMID: 1753156
-
Elimination of variable vasomotor tone in studies with repeated quantitative coronary angiography.Int J Card Imaging. 1990;5(2-3):125-34. doi: 10.1007/BF01833981. Int J Card Imaging. 1990. PMID: 2121843
-
Correlations between quantitative cineangiography, coronary flow reserve measured with digital subtraction cineangiography and exercise thallium perfusion scintigraphy.Int J Card Imaging. 1988;3(2-3):133-9. doi: 10.1007/BF01814886. Int J Card Imaging. 1988. PMID: 3049845
-
The impact of vessel orientation in space on densitometric measurements of cross sectional areas of coronary arteries.Int J Card Imaging. 1996 Dec;12(4):289-97. doi: 10.1007/BF01797742. Int J Card Imaging. 1996. PMID: 8993991
-
The impact of vessel and catheter position on the measurement accuracy in catheter-based quantitative coronary angiography.Int J Card Imaging. 1998 Aug;14(4):217-27. doi: 10.1023/a:1006067117225. Int J Card Imaging. 1998. PMID: 9934610
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources