Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Apr;65(2):338-344.
doi: 10.1111/tbed.12811. Epub 2018 Jan 16.

Development of a chemiluminescence immunoassay using recombinant non-structural epitope-based proteins to accurately differentiate foot-and-mouth disease virus-infected and vaccinated bovines

Affiliations

Development of a chemiluminescence immunoassay using recombinant non-structural epitope-based proteins to accurately differentiate foot-and-mouth disease virus-infected and vaccinated bovines

Z-Z Liu et al. Transbound Emerg Dis. 2018 Apr.

Erratum in

  • Corrigendum.
    [No authors listed] [No authors listed] Transbound Emerg Dis. 2018 Aug;65(4):1126. doi: 10.1111/tbed.12890. Transbound Emerg Dis. 2018. PMID: 29981220 No abstract available.

Abstract

The contamination of inactivated vaccine with non-structural proteins (NSPs) leads to a high false-positive rate, which is a substantial barrier to accurately differentiate foot-and-mouth disease virus (FMDV)-infected animals from vaccinated animals. To address this problem, a new chemiluminescence immunoassay (CLIA) method was developed to detect antibodies targeting the two recombinant epitope-based proteins located in 3A and 3B. The 3Aepitp-3Bepitp CLIA exhibited a diagnostic sensitivity of 94.0% and a diagnostic specificity of 97.5% for the detection of serum samples (naïve bovines, n = 52, vaccinated bovines, n = 422, infected bovines, n = 116) from animals with known status. The CLIA method also had a concordance rate of 88.1% with the PrioCHECK FMDV NSP ELISA based on the detection of 270 serum samples from the field. Importantly, the 3Aepitp-3Bepitp CLIA produced no false-positives when used to detect FMDV in samples from bovines that had been vaccinated up to five times, and it was demonstrated a low false-positive rate when the bovines had been vaccinated up to ten (2.15%) and fifteen times (5.93%). Therefore, the 3Aepitp-3Bepitp CLIA detects FMDV in samples from frequently vaccinated bovines with high accuracy and represents an alternative method to differentiate FMDV-infected and vaccinated bovines.

Keywords: 3Aepitope-3Bepitope; chemiluminescence immunoassay; diagnosis; foot-and-mouth disease virus.

PubMed Disclaimer

MeSH terms

LinkOut - more resources