Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2018;77(3):489-497.
doi: 10.5603/FM.a2018.0002. Epub 2018 Jan 18.

Evaluation of the morphological characteristic and sex differences of sternum by multi-detector computed tomography

Affiliations
Clinical Trial

Evaluation of the morphological characteristic and sex differences of sternum by multi-detector computed tomography

S Ateşoğlu et al. Folia Morphol (Warsz). 2018.

Abstract

Background: Sternum is one of the skeleton parts which have frequently congenital anomalies and variations are commonly used by researchers in determining sex. We evaluated the morphological characteristics and sex-related changes of the sternum in adult individuals using multidetector computed tomography in our study.

Materials and methods: Two hundred adults (103 female and 97 male) aged between 18 and 87 years were evaluated. Utilising the morphological characteristics of the sternum based on the multislice images; length, width and the thickness of manubrium, length, width and the thickness of corpus sterni, total length of sternum, sternal angle, sternal index (SI), length of the xiphoid process, the thickness of xiphoid process, the number of indents of xiphoid process were measured and a total of 20 parameters were evaluated by adding age, height and weight to these variables.

Results: The mean length of the manubrium, the length of corpus sterni, the length of total sternum, SI, sternal angle were found in females 46.7 ± 5.1, 86.6 ± 9.7, 133.1 ± 1.1, 54.47 ± 10.0 and 163.75 ± 5.79; in males 51.2 ± 6,102.4 ± 13.3, 154.1 ± 13.1, 50.11 ± 10.02 and 162.21 ± 6.17, respectively. We found that Hyrtl's Law and SI did not provide adequate accuracy for sex determination in our patients. It has been detected that the length of the manubrium alone is not helpful for individual samples. Total length of the sternum was found to be more reliable than the length of the manubrium and the length of corpus sterni. We determined sternal cleft and sternal foramen as 0.5% and 3.5%, respectively.

Conclusions: We suggest that the morphometric standards cannot be universally applied and can demonstrate individual differences. The standard rules must be implemented for every population.

Keywords: morphometric analysis; multidetector computed tomography; sex; sternal variations; sternum.

PubMed Disclaimer

Similar articles

Cited by

Publication types

Supplementary concepts

LinkOut - more resources