Background: Acetabular fractures are amongst the most challenging fractures to treat because of complex anatomy. Open reduction and internal fixation remains the standard treatment for displaced acetabular fractures to achieve anatomical reduction as in any other intra-articular fracture. Patient-specific pre-contoured reconstruction plate template made by a pre-operative virtual surgical planning can be useful to respect patient's morphology, reduce surgical invasiveness and simplify the surgical procedure. Proper evaluation and surgical planning is necessary to achieve these goals. The goal of this study was to evaluate the outcomes of using virtual surgical planning and virtually pre-contoured plate template in comparison with the conventional method of intra-operative contouring of reconstruction plate for acetabular fracture fixation.
Methods: Twenty-five patients were categorized into group A and B by computerized randomization. In group A (12 patients), CT-based virtual surgical planning was done using Mimics and 3-Matic software to form virtually pre-contoured plates, which were 3D printed to act as templates over which 3.5 mm reconstruction plates were manually contoured pre-operatively and used for fixation. In group B (13 patient), conventional method of intra-operative contouring to adapt the plate to the fracture region was followed. Blood loss, surgical time, reduction on X-rays and post-operative computed tomography were compared between two groups.
Results: Duration of surgery and total blood loss were found to be less while reduction was found to satisfactory/anatomical in higher percentage of Group A than Group B patients.
Conclusions: Virtual surgical planning, patient-specific virtually pre-contoured plate template and 3D printing technology improve the outcomes of acetabular fracture surgery by reducing duration and invasiveness of surgery and improving the quality of reduction. However, studies with larger sample size are required to further validate it.
Keywords: 3D model; 3D printing; Acetabular fracture; Plate template; Pre-contoured plate; Virtual surgical planning.
Similar articles
-
Application of computer-assisted virtual surgical procedures and three-dimensional printing of patient-specific pre-contoured plates in bicolumnar acetabular fracture fixation.Orthop Traumatol Surg Res. 2019 Sep;105(5):877-884. doi: 10.1016/j.otsr.2019.05.011. Epub 2019 Jul 9. Orthop Traumatol Surg Res. 2019. PMID: 31300239
-
Three-dimensional printing and patient-specific pre-contoured plate: future of acetabulum fracture fixation?Eur J Trauma Emerg Surg. 2018 Apr;44(2):215-224. doi: 10.1007/s00068-016-0738-6. Epub 2016 Oct 26. Eur J Trauma Emerg Surg. 2018. PMID: 27785534 Clinical Trial.
-
[Virtual preoperative planning and 3D-printed templates for pre-contoured plates in treatment of acetabular posterior wall fractures].Zhongguo Gu Shang. 2024 Feb 25;37(2):135-41. doi: 10.12200/j.issn.1003-0034.20220508. Zhongguo Gu Shang. 2024. PMID: 38425063 Chinese.
-
Use of 3D printing and pre-contouring plate in the surgical planning of acetabular fractures: A systematic review.Orthop Traumatol Surg Res. 2022 Apr;108(2):103111. doi: 10.1016/j.otsr.2021.103111. Epub 2021 Oct 11. Orthop Traumatol Surg Res. 2022. PMID: 34648997
-
Computer assisted surgery in preoperative planning of acetabular fracture surgery: state of the art.Expert Rev Med Devices. 2018 Jan;15(1):81-89. doi: 10.1080/17434440.2017.1413347. Epub 2017 Dec 10. Expert Rev Med Devices. 2018. PMID: 29206497 Review.
Cited by
-
Three-dimensional printing combined with open reduction and internal fixation versus open reduction and internal fixation in the treatment of acetabular fractures: A systematic review and meta-analysis.Chin J Traumatol. 2021 May;24(3):159-168. doi: 10.1016/j.cjtee.2021.02.007. Epub 2021 Feb 27. Chin J Traumatol. 2021. PMID: 33678536 Free PMC article.
-
The Clinical Efficacy of Contouring Periarticular Plates on a 3D Printed Bone Model.J Pers Med. 2023 Jul 17;13(7):1145. doi: 10.3390/jpm13071145. J Pers Med. 2023. PMID: 37511758 Free PMC article.
-
A New Diagnostic Approach for Periprosthetic Acetabular Fractures Based on 3D Modeling: A Study Protocol.Diagnostics (Basel). 2019 Dec 29;10(1):15. doi: 10.3390/diagnostics10010015. Diagnostics (Basel). 2019. PMID: 31905717 Free PMC article.
-
Clinical Applications of 3-Dimensional Printing Technology in Hip Joint.Orthop Surg. 2019 Aug;11(4):533-544. doi: 10.1111/os.12468. Epub 2019 Jul 18. Orthop Surg. 2019. PMID: 31321905 Free PMC article. Review.
-
Pre-contoured Plate Fit Assessment for Acetabular Fractures.Ann Biomed Eng. 2025 Sep;53(9):2299-2308. doi: 10.1007/s10439-025-03760-9. Epub 2025 May 26. Ann Biomed Eng. 2025. PMID: 40419857 Free PMC article.