. 2018 Jan 18;11(1):48-52.
doi: 10.18240/ijo.2018.01.09. eCollection 2018.

5-year follow-up of combined non-topography guided photorefractive keratectomy and corneal collagen cross linking for keratoconus

Affiliations

5-year follow-up of combined non-topography guided photorefractive keratectomy and corneal collagen cross linking for keratoconus

Abdulrahman Mohammed Al-Amri. Int J Ophthalmol. .

Abstract

Aim: To evaluate the visual outcomes of simultaneous non-topography guided photorefractive keratectomy (PRK) and corneal collagen cross-linking (CXL) in eyes with keratoconus 5y after the procedure.

Methods: Prospective, interventional, non-randomized, and non-controlled case series design was used. Sixty eyes of 30 patients (16 males and 14 females; age: 21-41y) with mild, non-progressive (stages 1-2) keratoconus were enrolled. Refraction, uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), flat and steep keratometry readings, and adverse events were evaluated preoperatively and postoperatively. Data were collected preoperatively and postoperatively at 3mo, 1, 2, 3, 4, and 5y follow-up visits after combined non-topography-guided PRK with CXL was performed. All patients had at least 5y of follow-up.

Results: All study parameters showed a statistically significant improvement at 5y over baseline values. The mean follow-up time was 68.20±4.71mo (range: 60-106mo). Patients showed a significant improvement in UDVA from 1.24±0.79 logMAR prior to combined non-TG-PRK+CXL to 0.06±0.15 logMAR postoperatively at the time of their last follow-up visit. CDVA significantly increased from 0.06±0.19 logMAR preoperatively to 0.03±0.12 logMAR postoperatively. A significant decrease in the mean spherical equivalent (SE) refraction was observed from -2.28±1.8 to -0.79±0.93 diopters (D) (P<0.05), and the manifest sphere decreased from -1.62±1.23 to -0.27±0.21 D (P=0.001). The manifest cylinder significantly decreased from -1.73±0.86 to -0.29±0.34 D postoperatively (P=0.001). The mean steep keratometry was 45.13±1.32 vs 47.28±2.12 D preoperatively (P<0.05), and the preoperative mean steepest keratometry (Kmax) 48.6±3.1 was reduced significantly to 46.8±2.9 postoperatively (P<0.05).

Conclusion: Combined non-TG-PRK with 15min CXL is an effective and safe option for correcting mild refractive error and improving visual acuity in patients with mild stable keratoconus.

Keywords: corneal collagen cross-linking; keratoconus; non-topography guided; photorefractive keratectomy.

PubMed Disclaimer

Figures

Figure 1
Figure 1. Gender distribution.
Figure 2
Figure 2. UDVA (logMAR) mean values.
Figure 3
Figure 3. CDVA (logMAR) mean values.
Figure 4
Figure 4. SE refraction (D) mean values.
Figure 5
Figure 5. Manifest cylinder (D) mean values.
Figure 6
Figure 6. Keratometry (D) steep mean values.
Figure 7
Figure 7. Keratometry (D) flat mean values.

References

    1. Rabinowitz YS. Keratoconus. Surv Ophthalmol. 1998;42(4):297–319. - PubMed
    1. Krachmer JH, Feder RS, Belin MW. Keratoconus and related noninflammatory corneal thinning disorders. Surv Ophthalmol. 1984;28(4):293–322. - PubMed
    1. Andreassen TT, Simonsen AH, Oxlund H. Biomechanical properties of keratoconus and normal corneas. Exp Eye Res. 1980;31(4):435–441. - PubMed
    1. Kanellopoulos AJ, Asimellis G. Revisiting keratoconus diagnosis and progression classification based on evaluation of corneal asymmetry indices, derived from Scheimpflug imaging in keratoconic and suspect cases. Clin Ophthalmol. 2013;7:1539–1548. - PMC - PubMed
    1. Miháltz K, Kovács I, Kránitz K, Erdei G, Németh J, Nagy ZZ. Mechanism of aberration balance and the effect on retinal image quality in keratoconus: optical and visual characteristics of keratoconus. J Cataract Refract Surg. 2011;7(5):914–922. - PubMed