Laser-Doppler flowmetry in the investigation of irritant compounds on human skin
Abstract
The value of laser-Doppler flowmetry was assessed in the evaluation of increased microvascular blood flow caused by the application of low concentrations of irritant compounds on the skin. Laser-Doppler flow values were compared with a visual scoring system for erythema and with skin vapour loss measurements. To this end patch tests were performed on the volar side of the forearm of 24 healthy Caucasian volunteers. The test substances were sodium lauryl sulphate 0.5 g/v%, 1 g/v%, 2 g/v% and phenol 5.0 g/v% in aqua dest. Distilled water served as a control. Laser-Doppler flow and skin vapour loss measurements were performed before and after an application time of 24 h. Data obtained with skin vapour loss measurements and with the visual scoring system demonstrated a statistically significant contribution of substance- as well as subject-related factors to the obtained scoring patterns. The results of laser-Doppler flow measurements were less consistent and could only partly be explained in this way, indicating that other factors also influence the microvascular blood flow in the skin. In this investigation laser-Doppler flowmetry and the visual scoring system were equally sensitive. The results of all three methods make it clear that (analogous to experience in daily life) barrier function impairment and inflammatory response caused by irritant compounds vary in different subjects. For the elucidation of the pathogenesis of irritant contact dermatitis further (longitudinal) investigations on the possible predictive value of skin blood flow measurements will be necessary.
Similar articles
-
After-work emollient creams: effects on irritant skin reactions.Derm Beruf Umwelt. 1987 May-Jun;35(3):95-8. Derm Beruf Umwelt. 1987. PMID: 3608827
-
Susceptibility of atopic dermatitis patients to irritant dermatitis caused by sodium lauryl sulphate.Acta Derm Venereol. 1991;71(4):296-300. Acta Derm Venereol. 1991. PMID: 1681644 Clinical Trial.
-
Effects of disinfectants and detergents on skin irritation.Contact Dermatitis. 2007 Oct;57(4):235-41. doi: 10.1111/j.1600-0536.2007.01200.x. Contact Dermatitis. 2007. PMID: 17868216
-
Laser-Doppler flowmetry.Crit Rev Biomed Eng. 1990;18(2):125-63. Crit Rev Biomed Eng. 1990. PMID: 2242676 Review.
-
[Laser Doppler blood flowmetry].Tidsskr Nor Laegeforen. 1991 Oct 10;111(24):2966-8. Tidsskr Nor Laegeforen. 1991. PMID: 1948903 Review. Norwegian.
Cited by
-
Assessment of skin erythema by eye, laser Doppler flowmeter, spectroradiometer, two-channel erythema meter and Minolta chroma meter.Arch Dermatol Res. 1993;285(5):278-82. doi: 10.1007/BF00371596. Arch Dermatol Res. 1993. PMID: 8379687