Comparing Dose-Length Product-Based and Monte Carlo Simulation Organ-Based Calculations of Effective Dose in 16- and 64-MDCT Examinations Using Automatic Tube Current Modulation
- PMID: 29381379
- DOI: 10.2214/AJR.17.18294
Comparing Dose-Length Product-Based and Monte Carlo Simulation Organ-Based Calculations of Effective Dose in 16- and 64-MDCT Examinations Using Automatic Tube Current Modulation
Abstract
Objective: The purpose of this study is to compare dose-length product (DLP)-based calculation of effective dose (EDDLP) with Monte Carlo simulation organ-based calculation of effective dose (EDMCO) in 16- and 64-MDCT examinations, with the use of clinical examinations with automatic tube current modulation.
Materials and methods: Dose data were obtained from 50 consecutive unenhanced head CT examinations, unenhanced chest CT examinations, and unenhanced and contrast-enhanced abdominopelvic CT examinations performed using 16- and 64-MDCT scanners, as well as from 50 pulmonary CT angiography (CTA) examinations performed using a 64-MDCT scanner and 31 pulmonary CTA examinations performed using a 16-MDCT scanner. The EDMCO and the mean patient effective diameter were calculated using commercially available software. The EDDLP was also calculated. Both the mean difference and percentage difference between EDDLP and EDMCO were calculated, and they were statistically compared according to patient sex, type of examination performed, and type of scanner used.
Results: EDDLP significantly underestimated the EDMCO by 0.3 mSv (19%) for men who underwent unenhanced head CT, 0.5 mSv (29%) for women who underwent unenhanced head CT, 0.9-1.4 mSv (9-13%) for men who underwent chest CT, and 4.7-4.8 mSv (39%) for women who underwent chest CT (p < 0.001). The EDDLP overestimated the EDMCO by 1.9-2.0 mSv (12-14%) for men who underwent abdominopelvic CT (p < 0.001), with no significant difference noted for women who underwent abdominopelvic CT's. No significant difference was noted in the percentage difference in ED between the 16- and 64-MDCT scanners (p ≥ 0.13).
Conclusion: EDDLP underestimates EDMCO, the reference standard for dose calculation, by 19-39% in unenhanced head CT examinations and, among women, in chest CT examinations. EDDLP deviates from EDMCO by less than 15% for chest CT examinations of men and for abdominopelvic CT. These differences can be attributed to variable patient body habitus, automatic tube current modulation, and sex-neutral k-coefficients, and they should be considered when calculating ED, particularly in women.
Keywords: CT; Monte Carlo; automatic tube current modulation; dose-length product; effective dose.
Similar articles
-
On the use of Monte Carlo-derived dosimetric data in the estimation of patient dose from CT examinations.Med Phys. 2008 May;35(5):2018-28. doi: 10.1118/1.2896075. Med Phys. 2008. PMID: 18561678
-
Prospective estimation of organ dose in CT under tube current modulation.Med Phys. 2015 Apr;42(4):1575-85. doi: 10.1118/1.4907955. Med Phys. 2015. PMID: 25832048 Free PMC article.
-
Radiation dose in a "triple rule-out" coronary CT angiography protocol of emergency department patients using 64-MDCT: the impact of ECG-based tube current modulation on age, sex, and body mass index.AJR Am J Roentgenol. 2009 Apr;192(4):866-72. doi: 10.2214/AJR.08.1758. AJR Am J Roentgenol. 2009. PMID: 19304688
-
Adult patient radiation doses from non-cardiac CT examinations: a review of published results.Br J Radiol. 2011 Apr;84(1000):293-303. doi: 10.1259/bjr/69070614. Epub 2011 Jan 25. Br J Radiol. 2011. PMID: 21266399 Free PMC article. Review.
-
A systematic review on the current status of adult diagnostic reference levels in head, chest and abdominopelvic Computed Tomography.J Radiol Prot. 2020 Sep;40(3):R71-R98. doi: 10.1088/1361-6498/ab826f. J Radiol Prot. 2020. PMID: 32203948
Cited by
-
Radiation Exposure in Operatively Treated Pediatric Femur Fracture Patients.J Pediatr Orthop. 2025 May-Jun 01;45(5):264-268. doi: 10.1097/BPO.0000000000002907. Epub 2025 Feb 4. J Pediatr Orthop. 2025. PMID: 39901620 Free PMC article.
-
Patient-Informed Organ Dose Estimation in Clinical CT: Implementation and Effective Dose Assessment in 1048 Clinical Patients.AJR Am J Roentgenol. 2021 Mar;216(3):824-834. doi: 10.2214/AJR.19.22482. Epub 2021 Jan 21. AJR Am J Roentgenol. 2021. PMID: 33474986 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical