Comparison of iodine-131 OIH and technetium-99m MAG3 renal imaging in volunteers
- PMID: 2940350
Comparison of iodine-131 OIH and technetium-99m MAG3 renal imaging in volunteers
Abstract
Animal studies have suggested that the nonisomeric N3S triamide mercaptide ligand, 99mTc mercaptoacetyltriglycine (MAG3), may provide a satisfactory 99mTc-labeled replacement for 131I hippurate (OIH). Sequential 30-min [99mTc]MAG3 (5-10 mCi) and [131I]OIH (300 microCi) imaging studies were performed in ten normal volunteers in order to compare the image quality, renal excretion, blood clearance, and time to peak height of the renogram curve. In addition, [99mTc] MAG3 (5 mCi) and [131I]OIH (150 microCi) were administered simultaneously in eight volunteers for comparison of 180-min blood and plasma clearances and urine excretion. In the sequential imaging studies, the blood clearance of [99mTc]MAG3 was more rapid than [131I]OIH with a mean clearance of 1.30 l/min compared with 0.88 l/min for [131I]OIH (p less than 0.05). Seventy-three percent of the injected dose of the MAG3 was excreted by 30 min compared with 66.8% for [131I]OIH. Whole kidney and cortical renogram curves showed no significant difference in the time to peak height for MAG3 and [131I]OIH. In all subjects, the quality of the [99mTc]MAG3 images were clearly superior to [131I]OIH. Following simultaneous injection, blood and plasma clearances for [131I]OIH were more rapid than MAG3 when determined for multiple time intervals from 0-30 to 0-180 min (p less than or equal to 0.05). The 0-30-min clearances of MAG3 and [131I]OIH were only slightly greater than the 0-180-min clearances and can be used to obtain valid comparisons of the two agents. As in the sequential study, 30-min urine excretion was greater for MAG3 than [131I]OIH (73.1 compared with 69.6%) but the difference was not statistically significant. Although the differences in the MAG3 clearances following sequential and simultaneous administration are not satisfactorily explained, the fact that both clearances were rapid, the MAG3 and OIH renogram curves were quite similar, and 30-min urine excretions of MAG3 and OIH were essentially identical suggests that MAG3 may become a 99mTc replacement for [13I]OIH and further clinical evaluation is warranted.
Similar articles
-
Evaluation of Tc-99m mercaptoacetyltriglycine in patients with impaired renal function.Radiology. 1987 Feb;162(2):365-70. doi: 10.1148/radiology.162.2.2948212. Radiology. 1987. PMID: 2948212
-
Comparison of technetium-99m MAG3 kit with HPLC-purified technetium-99m MAG3 and OIH in rats.J Nucl Med. 1987 Dec;28(12):1881-7. J Nucl Med. 1987. PMID: 2960790
-
99mTc-MAEC complexes: new renal radiopharmaceuticals combining characteristics of (99m)Tc-MAG3 and (99m)Tc-EC.J Nucl Med. 2004 May;45(5):885-91. J Nucl Med. 2004. PMID: 15136640
-
Technetium-99m (99mTc) mercaptoacetyltriglycine: update on the new 99mTc renal tubular function agent.Semin Nucl Med. 1992 Apr;22(2):61-73. doi: 10.1016/s0001-2998(05)80082-0. Semin Nucl Med. 1992. PMID: 1534184 Review.
-
Technetium-99m-EC and other potential new agents in renal nuclear medicine.Semin Nucl Med. 1999 Apr;29(2):91-101. doi: 10.1016/s0001-2998(99)80002-6. Semin Nucl Med. 1999. PMID: 10321823 Review.
Cited by
-
Reference Ranges in [(99m)Tc]Mercaptoacetyltriglycerine Renography: Comparison of a Semi-automated (Xeleris, GE) and Manual (Picker, Odyssey) Processing Software.Mol Imaging Biol. 2015 Oct;17(5):620-4. doi: 10.1007/s11307-014-0813-5. Mol Imaging Biol. 2015. PMID: 25693723
-
Diagnostic significance of semiquantitative and quantitative parameters of Tc99m-Ethylenedicystine renal allograft scintigraphy.Int Urol Nephrol. 2003;35(4):451-6. doi: 10.1023/b:urol.0000025623.36472.d8. Int Urol Nephrol. 2003. PMID: 15198143
-
Radionuclides in nephrourology, part 1: Radiopharmaceuticals, quality control, and quantitative indices.J Nucl Med. 2014 Apr;55(4):608-15. doi: 10.2967/jnumed.113.133447. Epub 2014 Feb 18. J Nucl Med. 2014. PMID: 24549283 Free PMC article. Review.
-
Evaluation of interobserver variability of parenchymal phase of Tc-99m mercaptoacetyltriglycine and Tc-99m dimercaptosuccinic acid renal scintigraphy.Indian J Nucl Med. 2014 Apr;29(2):87-91. doi: 10.4103/0972-3919.130288. Indian J Nucl Med. 2014. PMID: 24761059 Free PMC article.
-
Re(CO)3([18F]FEDA), a novel 18F PET renal tracer: Radiosynthesis and preclinical evaluation.Nucl Med Biol. 2018 Mar;58:42-50. doi: 10.1016/j.nucmedbio.2017.12.001. Epub 2017 Dec 27. Nucl Med Biol. 2018. PMID: 29367095 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials