Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2018 Jul;28(7):2812-2822.
doi: 10.1007/s00330-017-5292-z. Epub 2018 Feb 5.

Liver fibrosis: stretched exponential model outperforms mono-exponential and bi-exponential models of diffusion-weighted MRI

Affiliations
Comparative Study

Liver fibrosis: stretched exponential model outperforms mono-exponential and bi-exponential models of diffusion-weighted MRI

Nieun Seo et al. Eur Radiol. 2018 Jul.

Abstract

Objectives: To compare the ability of diffusion-weighted imaging (DWI) parameters acquired from three different models for the diagnosis of hepatic fibrosis (HF).

Methods: Ninety-five patients underwent DWI using nine b values at 3 T magnetic resonance. The hepatic apparent diffusion coefficient (ADC) from a mono-exponential model, the true diffusion coefficient (D t ), pseudo-diffusion coefficient (D p ) and perfusion fraction (f) from a biexponential model, and the distributed diffusion coefficient (DDC) and intravoxel heterogeneity index (α) from a stretched exponential model were compared with the pathological HF stage. For the stretched exponential model, parameters were also obtained using a dataset of six b values (DDC#, α#). The diagnostic performances of the parameters for HF staging were evaluated with Obuchowski measures and receiver operating characteristics (ROC) analysis. The measurement variability of DWI parameters was evaluated using the coefficient of variation (CoV).

Results: Diagnostic accuracy for HF staging was highest for DDC# (Obuchowski measures, 0.770 ± 0.03), and it was significantly higher than that of ADC (0.597 ± 0.05, p < 0.001), D t (0.575 ± 0.05, p < 0.001) and f (0.669 ± 0.04, p = 0.035). The parameters from stretched exponential DWI and D p showed higher areas under the ROC curve (AUCs) for determining significant fibrosis (≥F2) and cirrhosis (F = 4) than other parameters. However, D p showed significantly higher measurement variability (CoV, 74.6%) than DDC# (16.1%, p < 0.001) and α# (15.1%, p < 0.001).

Conclusions: Stretched exponential DWI is a promising method for HF staging with good diagnostic performance and fewer b-value acquisitions, allowing shorter acquisition time.

Key points: • Stretched exponential DWI provides a precise and accurate model for HF staging. • Stretched exponential DWI parameters are more reliable than D p from bi-exponential DWI model • Acquisition of six b values is sufficient to obtain accurate DDC and α.

Keywords: Diffusion magnetic resonance imaging; Fibrosis; Liver; Liver cirrhosis.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Radiology. 2017 Apr;283(1):98-107 - PubMed
    1. Radiology. 2015 Feb;274(2):405-15 - PubMed
    1. Eur Radiol. 2013 Feb;23(2):428-34 - PubMed
    1. J Hepatol. 2013 May;58(5):928-35 - PubMed
    1. Radiology. 1988 Aug;168(2):497-505 - PubMed

Publication types

LinkOut - more resources