Endoscopic Trigger Finger Release: Surgical Technique
- PMID: 29409419
- DOI: 10.1142/S2424835518710017
Endoscopic Trigger Finger Release: Surgical Technique
Abstract
Numerous surgical approaches have been described for treating patients suffering with stenosing tenosynovitis. The usual surgical descriptions differ mainly by the type of skin incision utilized. The goal of surgery is to completely release the A1 pulley, thereby allowing unimpeded motion of the flexor tendons. We describe a minimally invasive endoscopic technique to address this condition in the fingers.
Keywords: A1 pulley; Endoscopic; Finger; Release; Tenosynovitis; Trigger.
Comment in
-
Single-Portal Antegrade Endoscopic Trigger Finger Release: Cadaveric and Clinical Outcomes.Hand (N Y). 2024 Jul;19(5):823-830. doi: 10.1177/15589447221150512. Epub 2023 Feb 1. Hand (N Y). 2024. PMID: 36726337 Free PMC article.